{"id":7511,"date":"2026-07-16T06:40:42","date_gmt":"2026-07-16T06:40:42","guid":{"rendered":"https:\/\/korea-transmission.com\/?post_type=product&#038;p=7511"},"modified":"2026-07-20T09:55:07","modified_gmt":"2026-07-20T09:55:07","slug":"zq60-injection-blow-molding-machine-european","status":"publish","type":"product","link":"https:\/\/korea-transmission.com\/pt\/produto\/zq60-injection-blow-molding-machine-european\/","title":{"rendered":"M\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro ZQ60 (Europeia)"},"content":{"rendered":"<h2>M\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro ZQ60 (Europeia)<\/h2>\n<p>A m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro ZQ60 foi projetada com base em uma estrutura aut\u00eantica de estilo europeu, oferecendo estabilidade estrutural superior que estabelece um novo padr\u00e3o al\u00e9m dos modelos convencionais. Sua for\u00e7a de amortecimento \u00e9 aprimorada pelos componentes 20%-30% em compara\u00e7\u00e3o com os concorrentes do setor, suprimindo efetivamente a vibra\u00e7\u00e3o operacional para resultados de moldagem precisos e repet\u00edveis. O sistema de rota\u00e7\u00e3o servo padr\u00e3o da m\u00e1quina oferece uma arquitetura simplificada e opera\u00e7\u00e3o intuitiva, tornando-a a escolha ideal para fabricantes que buscam uma m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro de pl\u00e1stico de alto desempenho, capaz de atender \u00e0s exigentes demandas de produ\u00e7\u00e3o dos setores farmac\u00eautico, cosm\u00e9tico e de bebidas.<\/p>\n<p>No cora\u00e7\u00e3o da inova\u00e7\u00e3o da ZQ60 est\u00e1 sua estrutura exclusiva de fechamento pressurizado, que apresenta um design inovador onde o cilindro de refor\u00e7o \u00e9 completamente exclu\u00eddo do ciclo de abertura e fechamento do molde. Isso reduz o consumo de energia em 10%-20% em compara\u00e7\u00e3o com m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro convencionais, criando uma experi\u00eancia de produ\u00e7\u00e3o de alta efici\u00eancia e baixo consumo. Seja produzindo frascos de col\u00edrio de HDPE para linhas farmac\u00eauticas, recipientes cosm\u00e9ticos de PP ou garrafas de bebidas de PCTG de 1000ml, a ZQ60 oferece espessura de parede consistente, zero desperd\u00edcio de material e um tamanho compacto adequado aos ambientes de produ\u00e7\u00e3o modernos. Como uma m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro comprovada em uma \u00fanica etapa, ela combina inje\u00e7\u00e3o, sopro e desmoldagem em um \u00fanico ciclo sincronizado para m\u00e1xima produtividade com m\u00ednima perda de material.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-7431 size-full\" src=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine.webp\" alt=\"M\u00e1quina de Moldagem por Inje\u00e7\u00e3o e Sopro ZQ60\" width=\"800\" height=\"800\" srcset=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine.webp 800w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-480x480.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 800px, 100vw\" \/><\/p>\n<h2>Cavita\u00e7\u00e3o em moldes (para refer\u00eancia)<\/h2>\n<table style=\"width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" data-path-to-node=\"8\">\n<thead>\n<tr>\n<td style=\"text-align: center;\"><strong>Volume aproximado<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>10ml<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>30ml<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>60ml<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>100ml<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>250ml<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>500ml<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>1000ml<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: center;\"><span data-path-to-node=\"8,1,0,0\">Cavita\u00e7\u00e3o m\u00e1xima<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"8,1,1,0\">14<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"8,1,2,0\">10<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"8,1,3,0\">10<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"8,1,4,0\">8<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"8,1,5,0\">5<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"8,1,6,0\">3<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"8,1,7,0\">2<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Par\u00e2metros t\u00e9cnicos<\/h2>\n<table style=\"width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" data-path-to-node=\"11\">\n<thead>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><b>Item<\/b><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><strong>Unidade<\/strong><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><strong>ZQ60<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,1,0,0\"><b data-path-to-node=\"11,1,0,0\" data-index-in-node=\"0\">Sistema de Inje\u00e7\u00e3o<\/b><\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,2,0,0\">Di\u00e2metro do parafuso<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,2,1,0\">mil\u00edmetros<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,2,2,0\">45\/50<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,3,0,0\">Parafuso L\/D<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,3,1,0\">%<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,3,2,0\">22:1<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,4,0,0\">Peso da inje\u00e7\u00e3o!<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,4,1,0\">g<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,4,2,0\">260\/383<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,5,0,0\">Pot\u00eancia de aquecimento<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,5,1,0\">KW<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,5,2,0\">14<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,6,0,0\">N\u00famero de zonas de barril<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,6,2,0\">3+N<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,7,0,0\">acidente vascular cerebral por inje\u00e7\u00e3o<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,7,1,0\">mil\u00edmetros<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,7,2,0\">160<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,8,0,0\"><b data-path-to-node=\"11,8,0,0\" data-index-in-node=\"0\">Sistema de fixa\u00e7\u00e3o<\/b><\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,9,0,0\">For\u00e7a de fechamento da inje\u00e7\u00e3o<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,9,1,0\">KN<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,9,2,0\">600<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,10,0,0\">Golpe inicial para inje\u00e7\u00e3o<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,10,1,0\">mil\u00edmetros<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,10,2,0\">140<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,11,0,0\">For\u00e7a de sopro da l\u00e2mpada C<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,11,1,0\">KN<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,11,2,0\">100<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,12,0,0\">Golpe inicial para soprar<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,12,1,0\">mil\u00edmetros<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,12,2,0\">140<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,13,0,0\">Altura de eleva\u00e7\u00e3o da mesa rotativa<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,13,1,0\">mil\u00edmetros<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,13,2,0\">70<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,14,0,0\"><b data-path-to-node=\"11,14,0,0\" data-index-in-node=\"0\">Mofo<\/b><\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,15,0,0\">Tamanho m\u00e1ximo do prato (C x L)<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,15,1,0\">mil\u00edmetros<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,15,2,0\">600×390<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,16,0,0\">Espessura do molde<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,16,1,0\">mil\u00edmetros<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,16,2,0\">240<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,17,0,0\">Di\u00e2metro da garrafa<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,17,1,0\">mil\u00edmetros<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,17,2,0\">120<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,18,0,0\">Altura da garrafa<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,18,1,0\">mil\u00edmetros<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,18,2,0\">220<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,19,0,0\">Altura adequada da garrafa<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,19,1,0\">mil\u00edmetros<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,19,2,0\">15-200<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,20,0,0\">Golpe de despojamento<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,20,1,0\">mil\u00edmetros<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,20,2,0\">230<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,21,0,0\"><b data-path-to-node=\"11,21,0,0\" data-index-in-node=\"0\">Sistema hidr\u00e1ulico<\/b><\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,22,0,0\">Press\u00e3o hidr\u00e1ulica<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,22,1,0\">Mapa<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,22,2,0\">14<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,23,0,0\">Pot\u00eancia do motor<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,23,1,0\">KW<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,23,2,0\">18.5\/22<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,24,0,0\">Ciclo de secagem<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,24,1,0\">S<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,24,2,0\">4<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,25,0,0\">Pot\u00eancia Total<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,25,1,0\">KW<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,25,2,0\">37<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,26,0,0\">Pot\u00eancia operacional<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,26,1,0\">%<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,26,2,0\">52-70<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,27,0,0\"><b data-path-to-node=\"11,27,0,0\" data-index-in-node=\"0\">Outros<\/b><\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,28,0,0\">Press\u00e3o m\u00ednima do ar comprimido<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,28,1,0\">MPa<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,28,2,0\">0.7-1.2<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,29,0,0\">capacidade de ar comprimido<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,29,1,0\">M\u00b3\/min<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,29,2,0\">0.7<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,30,0,0\">Fluxo de \u00e1gua<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,30,1,0\">M\u00b3\/h<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,30,2,0\">4<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,31,0,0\">Press\u00e3o da \u00e1gua de refrigera\u00e7\u00e3o<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,31,1,0\">MPa<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,31,2,0\">0.3-0.4<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,32,0,0\">Dimens\u00f5es (C x L x A)<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,32,1,0\">M<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,32,2,0\">3.8×1.4×2.18<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 52.9271%;\"><span data-path-to-node=\"11,33,0,0\">Peso l\u00edquido<\/span><\/td>\n<td style=\"text-align: center; width: 15.8901%;\"><span data-path-to-node=\"11,33,1,0\">Tonelada<\/span><\/td>\n<td style=\"text-align: center; width: 30.9438%;\"><span data-path-to-node=\"11,33,2,0\">5<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Componentes da m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro ZQ60<\/h2>\n<table style=\"width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\">1<\/td>\n<td style=\"text-align: center;\">Dispositivo para prepara\u00e7\u00e3o\/inje\u00e7\u00e3o de estoque<\/td>\n<td style=\"text-align: center;\">2<\/td>\n<td style=\"text-align: center;\">Corredor Quente<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">3<\/td>\n<td style=\"text-align: center;\">Haste central<\/td>\n<td style=\"text-align: center;\">4<\/td>\n<td style=\"text-align: center;\">Pr\u00e9-forma de garrafa<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">5<\/td>\n<td style=\"text-align: center;\">Molde de Inje\u00e7\u00e3o<\/td>\n<td style=\"text-align: center;\">6<\/td>\n<td style=\"text-align: center;\">Posto de Inje\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">7<\/td>\n<td style=\"text-align: center;\">Esta\u00e7\u00e3o de Sopro<\/td>\n<td style=\"text-align: center;\">8<\/td>\n<td style=\"text-align: center;\">Moldagem por sopro<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">9<\/td>\n<td style=\"text-align: center;\">Esta\u00e7\u00e3o de strip-tease<\/td>\n<td style=\"text-align: center;\"><\/td>\n<td style=\"text-align: center;\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div>\n<h2>Marca e modelo substitu\u00edveis<\/h2>\n<\/div>\n<div>\n<table style=\"width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" data-path-to-node=\"1\">\n<thead>\n<tr>\n<td style=\"text-align: center; width: 14.8148%;\"><strong>CMN<\/strong><\/td>\n<td style=\"text-align: center; width: 18.7574%;\"><strong>For\u00e7a de aperto<\/strong><\/td>\n<td style=\"text-align: center; width: 15.8902%;\"><strong>Jomar<\/strong><\/td>\n<td style=\"text-align: center; width: 19.1158%;\"><strong>SUMA<\/strong><\/td>\n<td style=\"text-align: center; width: 13.2616%;\"><strong>Uniloy<\/strong><\/td>\n<td style=\"text-align: center; width: 17.9212%;\"><strong>Bloma<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: center; width: 14.8148%;\"><span data-path-to-node=\"1,1,0,0\">ZQ40<\/span><\/td>\n<td style=\"text-align: center; width: 18.7574%;\"><span data-path-to-node=\"1,1,1,0\">40T<\/span><\/td>\n<td style=\"text-align: center; width: 15.8902%;\"><span data-path-to-node=\"1,1,2,0\">IBM40<\/span><\/td>\n<td style=\"text-align: center; width: 19.1158%;\"><span data-path-to-node=\"1,1,3,0\">40iB<\/span><\/td>\n<td style=\"text-align: center; width: 13.2616%;\"><span data-path-to-node=\"1,1,4,0\">UIB70<\/span><\/td>\n<td style=\"text-align: center; width: 17.9212%;\"><span data-path-to-node=\"1,1,5,0\">IBM45<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.8148%;\"><span data-path-to-node=\"1,2,0,0\">ZQ60<\/span><\/td>\n<td style=\"text-align: center; width: 18.7574%;\"><span data-path-to-node=\"1,2,1,0\">60T<\/span><\/td>\n<td style=\"text-align: center; width: 15.8902%;\"><span data-path-to-node=\"1,2,2,0\">IBM65<\/span><\/td>\n<td style=\"text-align: center; width: 19.1158%;\"><span data-path-to-node=\"1,2,3,0\">65iB<\/span><\/td>\n<td style=\"text-align: center; width: 13.2616%;\"><span data-path-to-node=\"1,2,4,0\">UIB90<\/span><\/td>\n<td style=\"text-align: center; width: 17.9212%;\"><span data-path-to-node=\"1,2,5,0\">IBM50<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.8148%;\"><span data-path-to-node=\"1,3,0,0\">ZQ80<\/span><\/td>\n<td style=\"text-align: center; width: 18.7574%;\"><span data-path-to-node=\"1,3,1,0\">80T<\/span><\/td>\n<td style=\"text-align: center; width: 15.8902%;\"><span data-path-to-node=\"1,3,2,0\">IBM85S<\/span><\/td>\n<td style=\"text-align: center; width: 19.1158%;\"><span data-path-to-node=\"1,3,3,0\">85iB<\/span><\/td>\n<td style=\"text-align: center; width: 13.2616%;\"><span data-path-to-node=\"1,3,4,0\">UIB120<\/span><\/td>\n<td style=\"text-align: center; width: 17.9212%;\"><span data-path-to-node=\"1,3,5,0\">IBM85<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.8148%;\"><span data-path-to-node=\"1,4,0,0\">ZQ110<\/span><\/td>\n<td style=\"text-align: center; width: 18.7574%;\"><span data-path-to-node=\"1,4,1,0\">110T<\/span><\/td>\n<td style=\"text-align: center; width: 15.8902%;\"><span data-path-to-node=\"1,4,2,0\">IBM135<\/span><\/td>\n<td style=\"text-align: center; width: 19.1158%;\"><span data-path-to-node=\"1,4,3,0\">135iB<\/span><\/td>\n<td style=\"text-align: center; width: 13.2616%;\"><span data-path-to-node=\"1,4,4,0\">UIB150<\/span><\/td>\n<td style=\"text-align: center; width: 17.9212%;\"><span data-path-to-node=\"1,4,5,0\">IBM135<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 14.8148%;\"><span data-path-to-node=\"1,5,0,0\">ZQ135<\/span><\/td>\n<td style=\"text-align: center; width: 18.7574%;\"><span data-path-to-node=\"1,5,1,0\">135T<\/span><\/td>\n<td style=\"text-align: center; width: 15.8902%;\"><span data-path-to-node=\"1,5,2,0\">IBM175<\/span><\/td>\n<td style=\"text-align: center; width: 19.1158%;\"><span data-path-to-node=\"1,5,3,0\">175iB<\/span><\/td>\n<td style=\"text-align: center; width: 13.2616%;\"><span data-path-to-node=\"1,5,4,0\">UIB180<\/span><\/td>\n<td style=\"text-align: center; width: 17.9212%;\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 data-path-to-node=\"2\">Di\u00e2metro do parafuso da m\u00e1quina IBM<\/h3>\n<div id=\"model-response-message-contentr_47a1662a06fc8a7d\" class=\"markdown markdown-main-panel enable-luminous-fast-follows enable-updated-hr-color stronger\" dir=\"ltr\" aria-busy=\"false\" aria-live=\"off\">\n<table style=\"width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" data-path-to-node=\"1\">\n<thead>\n<tr>\n<td style=\"width: 15.0042%; text-align: center;\"><strong>CMN<\/strong><\/td>\n<td style=\"width: 21.4239%; text-align: center;\"><strong>Di\u00e2metro do parafuso<\/strong><\/td>\n<td style=\"width: 20.4188%; text-align: center;\"><strong>Jomar<\/strong><\/td>\n<td style=\"width: 20.744%; text-align: center;\"><strong>SUMA<\/strong><\/td>\n<td style=\"width: 22.1726%; text-align: center;\"><strong>Bloma<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"width: 15.0042%; text-align: center;\"><span data-path-to-node=\"1,1,0,0\">ZQ40<\/span><\/td>\n<td style=\"width: 21.4239%; text-align: center;\"><span data-path-to-node=\"1,1,1,0\">40\/45<\/span><\/td>\n<td style=\"width: 20.4188%; text-align: center;\"><span data-path-to-node=\"1,1,2,0\">35\/40<\/span><\/td>\n<td style=\"width: 20.744%; text-align: center;\"><span data-path-to-node=\"1,1,3,0\">40<\/span><\/td>\n<td style=\"width: 22.1726%; text-align: center;\"><span data-path-to-node=\"1,1,4,0\">45<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 15.0042%; text-align: center;\"><span data-path-to-node=\"1,2,0,0\">ZQ60<\/span><\/td>\n<td style=\"width: 21.4239%; text-align: center;\"><span data-path-to-node=\"1,2,1,0\">45\/50<\/span><\/td>\n<td style=\"width: 20.4188%; text-align: center;\"><span data-path-to-node=\"1,2,2,0\">45<\/span><\/td>\n<td style=\"width: 20.744%; text-align: center;\"><span data-path-to-node=\"1,2,3,0\">40\/50<\/span><\/td>\n<td style=\"width: 22.1726%; text-align: center;\"><span data-path-to-node=\"1,2,4,0\">50<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 15.0042%; text-align: center;\"><span data-path-to-node=\"1,3,0,0\">ZQ80<\/span><\/td>\n<td style=\"width: 21.4239%; text-align: center;\"><span data-path-to-node=\"1,3,1,0\">55<\/span><\/td>\n<td style=\"width: 20.4188%; text-align: center;\"><span data-path-to-node=\"1,3,2,0\">55<\/span><\/td>\n<td style=\"width: 20.744%; text-align: center;\"><span data-path-to-node=\"1,3,3,0\">50\/60<\/span><\/td>\n<td style=\"width: 22.1726%; text-align: center;\"><span data-path-to-node=\"1,3,4,0\">50<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 15.0042%; text-align: center;\"><span data-path-to-node=\"1,4,0,0\">ZQ110<\/span><\/td>\n<td style=\"width: 21.4239%; text-align: center;\"><span data-path-to-node=\"1,4,1,0\">65<\/span><\/td>\n<td style=\"width: 20.4188%; text-align: center;\"><span data-path-to-node=\"1,4,2,0\">65<\/span><\/td>\n<td style=\"width: 20.744%; text-align: center;\"><span data-path-to-node=\"1,4,3,0\">65\/76<\/span><\/td>\n<td style=\"width: 22.1726%; text-align: center;\"><span data-path-to-node=\"1,4,4,0\">70<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 15.0042%; text-align: center;\"><span data-path-to-node=\"1,5,0,0\">ZQ135<\/span><\/td>\n<td style=\"width: 21.4239%; text-align: center;\"><span data-path-to-node=\"1,5,1,0\">70<\/span><\/td>\n<td style=\"width: 20.4188%; text-align: center;\"><span data-path-to-node=\"1,5,2,0\">70<\/span><\/td>\n<td style=\"width: 20.744%; text-align: center;\"><span data-path-to-node=\"1,5,3,0\">65\/76<\/span><\/td>\n<td style=\"width: 22.1726%; text-align: center;\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div id=\"model-response-message-contentr_d0fcfe8c042b2e56\" class=\"markdown markdown-main-panel enable-luminous-fast-follows enable-updated-hr-color stronger\" dir=\"ltr\" aria-busy=\"false\" aria-live=\"off\">\n<h3 data-path-to-node=\"2\">Peso de inje\u00e7\u00e3o da m\u00e1quina IBM<\/h3>\n<table style=\"width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" data-path-to-node=\"4\">\n<thead>\n<tr>\n<td style=\"width: 14.3369%; text-align: center;\"><strong>CMN<\/strong><\/td>\n<td style=\"width: 23.178%; text-align: center;\"><strong>Peso da Inje\u00e7\u00e3o<\/strong><\/td>\n<td style=\"width: 18.5185%; text-align: center;\"><strong>Jomar<\/strong><\/td>\n<td style=\"width: 21.8638%; text-align: center;\"><strong>SUMA<\/strong><\/td>\n<td style=\"width: 22.1028%; text-align: center;\"><strong>Bloma<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"width: 14.3369%; text-align: center;\"><span data-path-to-node=\"4,1,0,0\">ZQ40<\/span><\/td>\n<td style=\"width: 23.178%; text-align: center;\"><span data-path-to-node=\"4,1,1,0\">190\/260<\/span><\/td>\n<td style=\"width: 18.5185%; text-align: center;\"><span data-path-to-node=\"4,1,2,0\">180<\/span><\/td>\n<td style=\"width: 21.8638%; text-align: center;\"><span data-path-to-node=\"4,1,3,0\">169<\/span><\/td>\n<td style=\"width: 22.1028%; text-align: center;\"><span data-path-to-node=\"4,1,4,0\">180<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 14.3369%; text-align: center;\"><span data-path-to-node=\"4,2,0,0\">ZQ60<\/span><\/td>\n<td style=\"width: 23.178%; text-align: center;\"><span data-path-to-node=\"4,2,1,0\">260\/383<\/span><\/td>\n<td style=\"width: 18.5185%; text-align: center;\"><span data-path-to-node=\"4,2,2,0\">205<\/span><\/td>\n<td style=\"width: 21.8638%; text-align: center;\"><span data-path-to-node=\"4,2,3,0\">169\/264<\/span><\/td>\n<td style=\"width: 22.1028%; text-align: center;\"><span data-path-to-node=\"4,2,4,0\">240<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 14.3369%; text-align: center;\"><span data-path-to-node=\"4,3,0,0\">ZQ80<\/span><\/td>\n<td style=\"width: 23.178%; text-align: center;\"><span data-path-to-node=\"4,3,1,0\">466<\/span><\/td>\n<td style=\"width: 18.5185%; text-align: center;\"><span data-path-to-node=\"4,3,2,0\">300<\/span><\/td>\n<td style=\"width: 21.8638%; text-align: center;\"><span data-path-to-node=\"4,3,3,0\">333\/480<\/span><\/td>\n<td style=\"width: 22.1028%; text-align: center;\"><span data-path-to-node=\"4,3,4,0\">310\/280<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 14.3369%; text-align: center;\"><span data-path-to-node=\"4,4,0,0\">ZQ110<\/span><\/td>\n<td style=\"width: 23.178%; text-align: center;\"><span data-path-to-node=\"4,4,1,0\">540<\/span><\/td>\n<td style=\"width: 18.5185%; text-align: center;\"><span data-path-to-node=\"4,4,2,0\">450\/550<\/span><\/td>\n<td style=\"width: 21.8638%; text-align: center;\"><span data-path-to-node=\"4,4,3,0\">580\/770<\/span><\/td>\n<td style=\"width: 22.1028%; text-align: center;\"><span data-path-to-node=\"4,4,4,0\">560<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 14.3369%; text-align: center;\"><span data-path-to-node=\"4,5,0,0\">ZQ135<\/span><\/td>\n<td style=\"width: 23.178%; text-align: center;\"><span data-path-to-node=\"4,5,1,0\">650<\/span><\/td>\n<td style=\"width: 18.5185%; text-align: center;\"><span data-path-to-node=\"4,5,2,0\">450\/550<\/span><\/td>\n<td style=\"width: 21.8638%; text-align: center;\"><span data-path-to-node=\"4,5,3,0\">580\/770<\/span><\/td>\n<td style=\"width: 22.1028%; text-align: center;\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div id=\"model-response-message-contentr_aa970ad8e091892c\" class=\"markdown markdown-main-panel enable-luminous-fast-follows enable-updated-hr-color stronger\" dir=\"ltr\" aria-busy=\"false\" aria-live=\"off\">\n<h3 data-path-to-node=\"2\">For\u00e7a de fechamento da inje\u00e7\u00e3o da m\u00e1quina IBM<\/h3>\n<table style=\"width: 100%; height: 138px;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" data-path-to-node=\"5\">\n<thead>\n<tr style=\"height: 23px;\">\n<td style=\"text-align: center; width: 13.6201%; height: 23px;\"><strong>CMN<\/strong><\/td>\n<td style=\"text-align: center; width: 23.178%; height: 23px;\"><strong>For\u00e7a de fechamento da inje\u00e7\u00e3o<\/strong><\/td>\n<td style=\"text-align: center; width: 21.6249%; height: 23px;\"><strong>Jomar<\/strong><\/td>\n<td style=\"text-align: center; width: 21.8639%; height: 23px;\"><strong>SUMA<\/strong><\/td>\n<td style=\"text-align: center; width: 19.4743%; height: 23px;\"><strong>Bloma<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"height: 23px;\">\n<td style=\"text-align: center; width: 13.6201%; height: 23px;\"><span data-path-to-node=\"5,1,0,0\">ZQ40<\/span><\/td>\n<td style=\"text-align: center; width: 23.178%; height: 23px;\"><span data-path-to-node=\"5,1,1,0\">400 kN<\/span><\/td>\n<td style=\"text-align: center; width: 21.6249%; height: 23px;\"><span data-path-to-node=\"5,1,2,0\">340 kN<\/span><\/td>\n<td style=\"text-align: center; width: 21.8639%; height: 23px;\"><span data-path-to-node=\"5,1,3,0\">386 kN<\/span><\/td>\n<td style=\"text-align: center; width: 19.4743%; height: 23px;\"><span data-path-to-node=\"5,1,4,0\">350 kN<\/span><\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"text-align: center; width: 13.6201%; height: 23px;\"><span data-path-to-node=\"5,2,0,0\">ZQ60<\/span><\/td>\n<td style=\"text-align: center; width: 23.178%; height: 23px;\"><span data-path-to-node=\"5,2,1,0\">600 kN<\/span><\/td>\n<td style=\"text-align: center; width: 21.6249%; height: 23px;\"><span data-path-to-node=\"5,2,2,0\">460 kN<\/span><\/td>\n<td style=\"text-align: center; width: 21.8639%; height: 23px;\"><span data-path-to-node=\"5,2,3,0\">580 kN<\/span><\/td>\n<td style=\"text-align: center; width: 19.4743%; height: 23px;\"><span data-path-to-node=\"5,2,4,0\">500 kN<\/span><\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"text-align: center; width: 13.6201%; height: 23px;\"><span data-path-to-node=\"5,3,0,0\">ZQ80<\/span><\/td>\n<td style=\"text-align: center; width: 23.178%; height: 23px;\"><span data-path-to-node=\"5,3,1,0\">800 kN<\/span><\/td>\n<td style=\"text-align: center; width: 21.6249%; height: 23px;\"><span data-path-to-node=\"5,3,2,0\">680 kN<\/span><\/td>\n<td style=\"text-align: center; width: 21.8639%; height: 23px;\"><span data-path-to-node=\"5,3,3,0\">720 kN<\/span><\/td>\n<td style=\"text-align: center; width: 19.4743%; height: 23px;\"><span data-path-to-node=\"5,3,4,0\">700 kN<\/span><\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"text-align: center; width: 13.6201%; height: 23px;\"><span data-path-to-node=\"5,4,0,0\">ZQ110<\/span><\/td>\n<td style=\"text-align: center; width: 23.178%; height: 23px;\"><span data-path-to-node=\"5,4,1,0\">1100 kN<\/span><\/td>\n<td style=\"text-align: center; width: 21.6249%; height: 23px;\"><span data-path-to-node=\"5,4,2,0\">1210 kN<\/span><\/td>\n<td style=\"text-align: center; width: 21.8639%; height: 23px;\"><span data-path-to-node=\"5,4,3,0\">1200 kN<\/span><\/td>\n<td style=\"text-align: center; width: 19.4743%; height: 23px;\"><span data-path-to-node=\"5,4,4,0\">1250 kN<\/span><\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"text-align: center; width: 13.6201%; height: 23px;\"><span data-path-to-node=\"5,5,0,0\">ZQ135<\/span><\/td>\n<td style=\"text-align: center; width: 23.178%; height: 23px;\"><span data-path-to-node=\"5,5,1,0\">1350 kN<\/span><\/td>\n<td style=\"text-align: center; width: 21.6249%; height: 23px;\"><span data-path-to-node=\"5,5,2,0\">1560 kN<\/span><\/td>\n<td style=\"text-align: center; width: 21.8639%; height: 23px;\"><span data-path-to-node=\"5,5,3,0\">1600 kN<\/span><\/td>\n<td style=\"text-align: center; width: 19.4743%; height: 23px;\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div id=\"model-response-message-contentr_bb408ce7925949a5\" class=\"markdown markdown-main-panel enable-luminous-fast-follows enable-updated-hr-color stronger\" dir=\"ltr\" aria-busy=\"false\" aria-live=\"off\">\n<h3 data-path-to-node=\"2\">Tamanho do molde da m\u00e1quina IBM<\/h3>\n<table style=\"width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" data-path-to-node=\"5\">\n<thead>\n<tr>\n<td style=\"text-align: center;\"><strong>CMN<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Tamanho do molde<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Jomar<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>SUMA<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Bloma<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,1,0,0\">ZQ40<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,1,1,0\">480 \u00d7 340<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,1,2,0\">394 \u00d7 508<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,1,3,0\">470 \u00d7 350<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,1,4,0\">450 \u00d7 390<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,2,0,0\">ZQ60<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,2,1,0\">600 \u00d7 390<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,2,2,0\">432 \u00d7 660<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,2,3,0\">620 \u00d7 400<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,2,4,0\">620 \u00d7 430<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,3,0,0\">ZQ80<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,3,1,0\">800 \u00d7 400<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,3,2,0\">464 \u00d7 749<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,3,3,0\">700 \u00d7 400<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,3,4,0\">620 \u00d7 430<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,4,0,0\">ZQ110<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,4,1,0\">1100 \u00d7 460<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,4,2,0\">559 \u00d7 1118<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,4,3,0\">1000 \u00d7 500<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,4,4,0\">900 \u00d7 480<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,5,0,0\">ZQ135<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,5,1,0\">1300 \u00d7 500<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,5,2,0\">635 \u00d7 1372<\/span><\/td>\n<td style=\"text-align: center;\"><span data-path-to-node=\"5,5,3,0\">1200 \u00d7 600<\/span><\/td>\n<td style=\"text-align: center;\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div id=\"model-response-message-contentr_3e94d2afa75a30a9\" class=\"markdown markdown-main-panel enable-luminous-fast-follows enable-updated-hr-color stronger\" dir=\"ltr\" aria-busy=\"false\" aria-live=\"polite\">\n<h3 data-path-to-node=\"2\">Tamanho da m\u00e1quina IBM<\/h3>\n<table style=\"width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" data-path-to-node=\"5\">\n<thead>\n<tr>\n<td style=\"text-align: center; width: 13.7395%;\"><strong>CMN<\/strong><\/td>\n<td style=\"text-align: center; width: 22.4612%;\"><strong>Tamanho do molde (M)<\/strong><\/td>\n<td style=\"text-align: center; width: 21.3859%;\"><strong>Jomar<\/strong><\/td>\n<td style=\"text-align: center; width: 21.6248%;\"><strong>SUMA<\/strong><\/td>\n<td style=\"text-align: center; width: 20.5496%;\"><strong>Bloma<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: center; width: 13.7395%;\"><span data-path-to-node=\"5,1,0,0\">ZQ40<\/span><\/td>\n<td style=\"text-align: center; width: 22.4612%;\"><span data-path-to-node=\"5,1,1,0\">3,8 \u00d7 1,3 \u00d7 1,7<\/span><\/td>\n<td style=\"text-align: center; width: 21.3859%;\"><span data-path-to-node=\"5,1,2,0\">2,72 \u00d7 1,9 \u00d7 2,75<\/span><\/td>\n<td style=\"text-align: center; width: 21.6248%;\"><span data-path-to-node=\"5,1,3,0\">3,8 \u00d7 1,5 \u00d7 2,3<\/span><\/td>\n<td style=\"text-align: center; width: 20.5496%;\"><span data-path-to-node=\"5,1,4,0\">4,05 \u00d7 1,52 \u00d7 2,55<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 13.7395%;\"><span data-path-to-node=\"5,2,0,0\">ZQ60<\/span><\/td>\n<td style=\"text-align: center; width: 22.4612%;\"><span data-path-to-node=\"5,2,1,0\">3,8 \u00d7 1,4 \u00d7 1,8<\/span><\/td>\n<td style=\"text-align: center; width: 21.3859%;\"><span data-path-to-node=\"5,2,2,0\">2,92 \u00d7 1,98 \u00d7 3,41<\/span><\/td>\n<td style=\"text-align: center; width: 21.6248%;\"><span data-path-to-node=\"5,2,3,0\">4 \u00d7 1,7 \u00d7 2,3<\/span><\/td>\n<td style=\"text-align: center; width: 20.5496%;\"><span data-path-to-node=\"5,2,4,0\">620 \u00d7 430 \u00d7 2,55<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 13.7395%;\"><span data-path-to-node=\"5,3,0,0\">ZQ80<\/span><\/td>\n<td style=\"text-align: center; width: 22.4612%;\"><span data-path-to-node=\"5,3,1,0\">4,5 \u00d7 1,6 \u00d7 2<\/span><\/td>\n<td style=\"text-align: center; width: 21.3859%;\"><span data-path-to-node=\"5,3,2,0\">3,33 \u00d7 1,94 \u00d7 3,41<\/span><\/td>\n<td style=\"text-align: center; width: 21.6248%;\"><span data-path-to-node=\"5,3,3,0\">4,5 \u00d7 2 \u00d7 2,6<\/span><\/td>\n<td style=\"text-align: center; width: 20.5496%;\"><span data-path-to-node=\"5,3,4,0\">620 \u00d7 430 \u00d7 2,55<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 13.7395%;\"><span data-path-to-node=\"5,4,0,0\">ZQ110<\/span><\/td>\n<td style=\"text-align: center; width: 22.4612%;\"><span data-path-to-node=\"5,4,1,0\">5 \u00d7 1,8 \u00d7 2,2<\/span><\/td>\n<td style=\"text-align: center; width: 21.3859%;\"><span data-path-to-node=\"5,4,2,0\">3,79 \u00d7 2,4 \u00d7 3,41<\/span><\/td>\n<td style=\"text-align: center; width: 21.6248%;\"><span data-path-to-node=\"5,4,3,0\">5 \u00d7 2,4 \u00d7 2,7<\/span><\/td>\n<td style=\"text-align: center; width: 20.5496%;\"><span data-path-to-node=\"5,4,4,0\">900 \u00d7 480 \u00d7 2,55<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; width: 13.7395%;\"><span data-path-to-node=\"5,5,0,0\">ZQ135<\/span><\/td>\n<td style=\"text-align: center; width: 22.4612%;\"><span data-path-to-node=\"5,5,1,0\">5,5 \u00d7 2 \u00d7 2,4<\/span><\/td>\n<td style=\"text-align: center; width: 21.3859%;\"><span data-path-to-node=\"5,5,2,0\">4,22 \u00d7 2,67 \u00d7 3,58<\/span><\/td>\n<td style=\"text-align: center; width: 21.6248%;\"><span data-path-to-node=\"5,5,3,0\">6 \u00d7 2,6 \u00d7 2,7<\/span><\/td>\n<td style=\"text-align: center; width: 20.5496%;\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p><strong>Nota: As marcas s\u00e3o mencionadas apenas para ajudar os clientes a escolher os produtos, n\u00e3o para vender os produtos dessas marcas.<\/strong><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h2>Caracter\u00edsticas da m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro totalmente el\u00e9trica ZQ60<\/h2>\n<p>1. Servoacionamento completo: Sem \u00f3leo hidr\u00e1ulico<br \/>\nTodos os movimentos desta m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro totalmente el\u00e9trica s\u00e3o servoacionados, eliminando completamente o uso de \u00f3leo hidr\u00e1ulico e os riscos de contamina\u00e7\u00e3o associados. Isso \u00e9 especialmente cr\u00edtico para embalagens farmac\u00eauticas e de contato com alimentos. A precis\u00e3o servo tamb\u00e9m significa repetibilidade excepcional por meio de encoders absolutos, permitindo uma precis\u00e3o de processamento em cada ciclo que supera a de m\u00e1quinas hidr\u00e1ulicas tradicionais. Os intervalos de manuten\u00e7\u00e3o s\u00e3o prolongados e o ru\u00eddo operacional \u00e9 significativamente reduzido, criando um ambiente de trabalho mais seguro e limpo, em conformidade com as normas GMP.<\/p>\n<p>2. Ciclo mais r\u00e1pido 20%, produ\u00e7\u00e3o de 105.000 garrafas\/dia<br \/>\nA m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro ZQ60 oferece um ciclo de produ\u00e7\u00e3o 20% mais r\u00e1pido em compara\u00e7\u00e3o com as m\u00e1quinas hidr\u00e1ulicas tradicionais. Para frascos de 30 ml, cada ciclo \u00e9 conclu\u00eddo em apenas 8,2 segundos, resultando em uma produ\u00e7\u00e3o di\u00e1ria de 105.000 frascos e uma capacidade m\u00e1xima de 115.000 frascos por 24 horas. Essa velocidade de produ\u00e7\u00e3o torna a ZQ60 uma das m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro mais competitivas do mercado, reduzindo drasticamente o custo por unidade e permitindo que os fabricantes atendam a grandes volumes de pedidos com confian\u00e7a e consist\u00eancia.<\/p>\n<p>3. Economia de energia 30%: Apenas 12 kWh\/hora<br \/>\nA efici\u00eancia energ\u00e9tica da 30% \u00e9 superior \u00e0 das m\u00e1quinas IBM convencionais, consumindo apenas 12 kWh por hora durante a produ\u00e7\u00e3o de garrafas de 30 ml. A inovadora estrutura de fixa\u00e7\u00e3o pressurizada mant\u00e9m o cilindro de refor\u00e7o fora do ciclo de abertura e fechamento, reduzindo ainda mais o consumo de energia dos modelos 10% a 20%. Para opera\u00e7\u00f5es de alto volume, funcionando 24 horas por dia, isso se traduz em economia substancial nos custos de eletricidade ao longo da vida \u00fatil da m\u00e1quina, proporcionando um excelente retorno sobre o investimento para qualquer fabricante de m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro que busque reduzir custos operacionais.<\/p>\n<p>4. For\u00e7a de fixa\u00e7\u00e3o ajust\u00e1vel (40-80 toneladas)<br \/>\nUm mecanismo de fechamento especial proporciona for\u00e7a de fechamento totalmente ajust\u00e1vel numa faixa de 40 a 80 toneladas, permitindo que esta m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro personalizada se adapte perfeitamente a diversas especifica\u00e7\u00f5es de produtos e designs de moldes. Seja produzindo pequenos frascos de col\u00edrio de 10 ml ou grandes recipientes de 1000 ml, os operadores podem ajustar o fechamento com precis\u00e3o para se adequar ao produto, reduzindo o desgaste do molde e prolongando a vida \u00fatil da ferramenta. Essa flexibilidade torna a ZQ60 uma verdadeira plataforma de m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro de est\u00e1gio \u00fanico multifuncional, ideal para fabricantes terceirizados que lidam com especifica\u00e7\u00f5es variadas de clientes.<\/p>\n<p>5. Projeto higi\u00eanico de baixo para cima para grau farmac\u00eautico<br \/>\nO design estrutural patenteado de baixo para cima impede fisicamente que o \u00f3leo lubrificante entre na zona do molde. Isso torna a ZQ60 uma das m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro de PET e pl\u00e1stico mais adequadas para o mercado. <a href=\"https:\/\/korea-transmission.com\/pt\/injection-blow-molding-machine\/\"><strong>m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro<\/strong><\/a> Para embalagens farmac\u00eauticas, frascos conta-gotas de grau cl\u00ednico e recipientes cosm\u00e9ticos premium que exigem zero contamina\u00e7\u00e3o. A m\u00e1quina atende a rigorosos requisitos de higiene e Boas Pr\u00e1ticas de Fabrica\u00e7\u00e3o (BPF) e \u00e9 ideal para ambientes onde a pureza do produto e a conformidade regulat\u00f3ria s\u00e3o requisitos indispens\u00e1veis \u200b\u200bpara o acesso ao mercado.<\/p>\n<p>6. Linha de produ\u00e7\u00e3o totalmente automatizada e integrada com sistema de vis\u00e3o.<br \/>\nO sistema de esteiras desta m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro integra-se diretamente com sistemas de inspe\u00e7\u00e3o visual que detectam part\u00edculas estranhas, material insuficiente no gargalo e fundos de garrafa irregulares. Tamb\u00e9m pode ser conectado a testadores de vazamento lateral, m\u00e1quinas de rotulagem autom\u00e1tica e equipamentos de embalagem rob\u00f3tica, permitindo opera\u00e7\u00e3o totalmente automatizada e sem supervis\u00e3o 24 horas por dia, 7 dias por semana. Essa capacidade de automa\u00e7\u00e3o completa reduz significativamente os custos de m\u00e3o de obra, ao mesmo tempo que garante a manuten\u00e7\u00e3o consistente dos padr\u00f5es de qualidade do produto, tornando-a uma das melhores op\u00e7\u00f5es de m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro para ambientes de produ\u00e7\u00e3o da Ind\u00fastria 4.0.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-7530 size-full\" src=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-2.webp\" alt=\"M\u00e1quina de Moldagem por Inje\u00e7\u00e3o e Sopro ZQ60\" width=\"1200\" height=\"1200\" srcset=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-2.webp 1200w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-2-980x980.webp 980w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-2-480x480.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1200px, 100vw\" \/><\/p>\n<h2>Princ\u00edpio de funcionamento da m\u00e1quina IBM ZQ60<\/h2>\n<p>1. Inje\u00e7\u00e3o de pr\u00e9-forma<br \/>\nNa primeira esta\u00e7\u00e3o, a resina pl\u00e1stica fundida \u00e9 injetada com precis\u00e3o na cavidade atrav\u00e9s do sistema de canais quentes. A rosca e o acabamento do gargalo da garrafa s\u00e3o moldados com exata precis\u00e3o dimensional nesta etapa, garantindo que cada pr\u00e9-forma saia do molde de inje\u00e7\u00e3o com gramatura e geometria de rosca consistentes. Assim que o tempo de inje\u00e7\u00e3o e o per\u00edodo de resfriamento predefinidos forem conclu\u00eddos, o molde de inje\u00e7\u00e3o se abre e o mandril com a pr\u00e9-forma formada \u00e9 indexado pela mesa rotativa servo para a esta\u00e7\u00e3o de moldagem por sopro. Essa transfer\u00eancia cont\u00ednua elimina qualquer etapa de reaquecimento, reduzindo o tempo de ciclo e a tens\u00e3o no material em compara\u00e7\u00e3o com um processo de m\u00e1quina ISBM de duas etapas.<\/p>\n<p>2. Moldagem por sopro<br \/>\nNa esta\u00e7\u00e3o de moldagem por sopro, o ar comprimido \u00e9 introduzido atrav\u00e9s do mandril a uma press\u00e3o precisamente controlada de 0,7 a 1,2 MPa. O ar for\u00e7a a pr\u00e9-forma, ainda quente, para fora at\u00e9 que o pl\u00e1stico se conforme exatamente ao formato da cavidade do molde de sopro. O n\u00famero de cavidades \u00e9 determinado pelo formato, volume e espessura de parede desejados para a garrafa. Ap\u00f3s a dura\u00e7\u00e3o especificada do sopro e o ciclo de resfriamento, o molde de sopro se abre e a mesa rotativa servo-assistida posiciona o mandril e a garrafa totalmente formada na esta\u00e7\u00e3o de desmoldagem. A estrutura de sopro de baixo para cima garante que a base convexa da garrafa seja formada de maneira consistente, com excelente estabilidade dimensional em todas as cavidades.<\/p>\n<p>3. Desmontagem e Eje\u00e7\u00e3o<br \/>\nNa esta\u00e7\u00e3o de desmoldagem, as garrafas resfriadas e totalmente moldadas s\u00e3o ejetadas automaticamente das hastes de n\u00facleo frio pelo mecanismo de desmoldagem e, em seguida, transportadas diretamente para a linha de produ\u00e7\u00e3o sem interven\u00e7\u00e3o do operador. As tr\u00eas a\u00e7\u00f5es simult\u00e2neas de inje\u00e7\u00e3o, sopro e desmoldagem operam em cada ciclo da m\u00e1quina, sem tempo morto entre as esta\u00e7\u00f5es. Esse design s\u00edncrono de tr\u00eas esta\u00e7\u00f5es \u00e9 o que torna a m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro ZQ60 uma plataforma de produ\u00e7\u00e3o de alta efici\u00eancia e zero desperd\u00edcio. N\u00e3o h\u00e1 aberturas em branco, rebarbas ou bordas descartadas em nenhum ponto do ciclo, resultando em consist\u00eancia de peso do produto dentro de aproximadamente 1% e uniformidade de espessura da parede que corresponde precisamente \u00e0 especifica\u00e7\u00e3o do projeto.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-7533 size-full\" src=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-5.webp\" alt=\"M\u00e1quina de Moldagem por Inje\u00e7\u00e3o e Sopro ZQ60\" width=\"1200\" height=\"720\" srcset=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-5.webp 1200w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-5-980x588.webp 980w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-5-480x288.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1200px, 100vw\" \/><\/p>\n<h2>Campos de inscri\u00e7\u00e3o<\/h2>\n<div>\n<h3>Frascos de produtos qu\u00edmicos<\/h3>\n<p>Os recipientes qu\u00edmicos industriais em HDPE e PP exigem excelente resist\u00eancia qu\u00edmica e dimens\u00f5es de rosca precisas para evitar vazamentos. O controle uniforme da espessura da parede e a forma\u00e7\u00e3o de rosca selada 100% tornam o ZQ60 ideal para a produ\u00e7\u00e3o de frascos para produtos de limpeza, solventes, lubrificantes e agroqu\u00edmicos em tamanhos de 30 ml a 1000 ml, com desvio de peso consistente de aproximadamente 1%.<\/p>\n<\/div>\n<div>\n<h3>Garrafas de bebidas<\/h3>\n<p>Para recipientes de bebidas de alta transpar\u00eancia em PS, PCTG e PET, incluindo garrafas para bact\u00e9rias l\u00e1ticas, garrafas de suco e bebidas saud\u00e1veis, a ZQ60 produz recipientes opticamente transparentes e dimensionalmente consistentes. O design higi\u00eanico em conformidade com as Boas Pr\u00e1ticas de Fabrica\u00e7\u00e3o (GMP) garante que nenhum \u00f3leo ou contaminante entre na zona de moldagem da garrafa, atendendo aos padr\u00f5es de seguran\u00e7a para contato com alimentos em mercados globais, incluindo Coreia, \u00cdndia e Brasil.<\/p>\n<\/div>\n<div>\n<h3>Frascos de cosm\u00e9ticos<\/h3>\n<p>As embalagens cosm\u00e9ticas premium exigem consist\u00eancia est\u00e9tica e integridade funcional. O sistema de inje\u00e7\u00e3o servo de precis\u00e3o ZQ60 produz frascos cosm\u00e9ticos com acabamento de superf\u00edcie impec\u00e1vel, sem rebarbas na linha de jun\u00e7\u00e3o e com roscas perfeitamente centradas. Ele \u00e9 igualmente capaz de produzir recipientes em ABS e PCTG para s\u00e9runs, lo\u00e7\u00f5es e produtos para a pele com especifica\u00e7\u00f5es est\u00e9ticas e dimensionais exigentes e com alto n\u00famero de cavidades.<\/p>\n<\/div>\n<div>\n<h3>Frascos farmac\u00eauticos<\/h3>\n<p>\u00c9 aqui que o design higi\u00eanico de baixo para cima da ZQ60 se mostra mais valioso. O isolamento f\u00edsico do sistema de lubrifica\u00e7\u00e3o da cavidade do molde atende \u00e0s normas de salas limpas Classe 100.000 e \u00e0s Boas Pr\u00e1ticas de Fabrica\u00e7\u00e3o (BPF). A m\u00e1quina produz frascos para l\u00edquidos orais, recipientes para c\u00e1psulas, frascos para comprimidos e frascos cl\u00ednicos em PEAD e PP, com precis\u00e3o dimensional absoluta e veda\u00e7\u00e3o 100% na boca do frasco para evitar contamina\u00e7\u00e3o em produtos farmac\u00eauticos.<\/p>\n<\/div>\n<div>\n<h3>Frascos de condimentos<\/h3>\n<p>Os recipientes para molho de soja, vinagre, molho picante e outros condimentos exigem excelente repetibilidade dimensional para compatibilidade com linhas automatizadas de envase e fechamento. A ZQ60 produz frascos para condimentos em HDPE e PP com bocas planas e sem rebarbas, al\u00e9m de di\u00e2metros de gargalo altamente uniformes, garantindo que as tampas se encaixem corretamente e os bicos de enchimento se alinhem com precis\u00e3o em velocidades de produ\u00e7\u00e3o superiores a 100.000 unidades por dia em configura\u00e7\u00f5es de moldes de alta cavita\u00e7\u00e3o.<\/p>\n<\/div>\n<div>\n<h3>Frascos conta-gotas<\/h3>\n<p>Os frascos conta-gotas e para solu\u00e7\u00f5es oft\u00e1lmicas representam algumas das especifica\u00e7\u00f5es mais exigentes em embalagens pl\u00e1sticas, requerendo volumes de gotas controlados, selos de rosca est\u00e9reis e materiais n\u00e3o reativos. Como uma alternativa l\u00edder em m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro para tampas de l\u00e2mpadas LED, voltada para recipientes de precis\u00e3o de pequeno volume, a ZQ60 se destaca na produ\u00e7\u00e3o de corpos de frascos conta-gotas em LDPE, PP e PCTG com superf\u00edcies de veda\u00e7\u00e3o impec\u00e1veis \u200b\u200be toler\u00e2ncias rigorosas em at\u00e9 14 cavidades para tamanhos de 10 ml.<\/p>\n<\/div>\n<div>\n<h3>Frascos de sabonete l\u00edquido<\/h3>\n<p>Frascos de grande formato para sabonete l\u00edquido, xampu e condicionador de cabelo em PP e HDPE exigem espessura uniforme nas paredes laterais para evitar o colapso sob a press\u00e3o da bomba dosadora. Os moldes multicavidades ZQ60 (at\u00e9 3 cavidades em frascos de 500 ml) produzem frascos para sabonete l\u00edquido com est\u00e9tica consistente e integridade estrutural. A for\u00e7a de fechamento ajust\u00e1vel da m\u00e1quina e a precis\u00e3o servo garantem que as dimens\u00f5es do gargalo e da rosca atendam \u00e0s especifica\u00e7\u00f5es padr\u00e3o de encaixe da bomba de forma confi\u00e1vel em todos os ciclos.<\/p>\n<\/div>\n<div>\n<h3>Frascos de pesticidas<\/h3>\n<p>Os recipientes para pesticidas agr\u00edcolas devem estar em conformidade com os regulamentos de transporte da ONU, possuir tampas inviol\u00e1veis \u200b\u200be resistir \u00e0 permea\u00e7\u00e3o de produtos qu\u00edmicos. Os materiais de HDPE e HDPE coextrudados na plataforma ZQ60 produzem frascos para pesticidas com excelentes propriedades de barreira qu\u00edmica, estrutura robusta de base convexa e dimens\u00f5es precisas de rosca \u00e0 prova de crian\u00e7as. O processo de produ\u00e7\u00e3o com zero desperd\u00edcio \u00e9 particularmente econ\u00f4mico no processamento de materiais de barreira especiais, onde o custo da mat\u00e9ria-prima \u00e9 elevado.<\/p>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 50%;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-7501 size-full\" src=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Pharmaceutical-Bottle-1.webp\" alt=\"Frasco farmac\u00eautico\" width=\"1200\" height=\"820\" srcset=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Pharmaceutical-Bottle-1.webp 1200w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Pharmaceutical-Bottle-1-980x670.webp 980w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Pharmaceutical-Bottle-1-480x328.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1200px, 100vw\" \/><\/td>\n<td style=\"width: 50%;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-7486 size-full\" src=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Food-Bottle-1.webp\" alt=\"Garrafa de comida\" width=\"1200\" height=\"820\" srcset=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Food-Bottle-1.webp 1200w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Food-Bottle-1-980x670.webp 980w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Food-Bottle-1-480x328.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1200px, 100vw\" \/><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; text-align: center;\"><strong>Frasco farmac\u00eautico<\/strong><\/td>\n<td style=\"width: 50%; text-align: center;\"><strong>Garrafa de comida<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-7497 size-full\" src=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Chemical-Bottle-1.webp\" alt=\"Frasco de produto qu\u00edmico\" width=\"1200\" height=\"820\" srcset=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Chemical-Bottle-1.webp 1200w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Chemical-Bottle-1-980x670.webp 980w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Chemical-Bottle-1-480x328.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1200px, 100vw\" \/><\/td>\n<td style=\"width: 50%; text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-7485 size-full\" src=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Cosmetic-Bottle-1.webp\" alt=\"Frasco cosm\u00e9tico\" width=\"1200\" height=\"820\" srcset=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Cosmetic-Bottle-1.webp 1200w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Cosmetic-Bottle-1-980x670.webp 980w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Cosmetic-Bottle-1-480x328.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1200px, 100vw\" \/><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; text-align: center;\"><strong>Frasco de produto qu\u00edmico<\/strong><\/td>\n<td style=\"width: 50%; text-align: center;\"><strong>Frasco cosm\u00e9tico<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Componentes principais<\/h2>\n<p>1. Dispositivo de Prepara\u00e7\u00e3o\/Inje\u00e7\u00e3o de Solu\u00e7\u00e3o Estoque<br \/>\nA unidade de inje\u00e7\u00e3o abriga uma rosca usinada com precis\u00e3o, com di\u00e2metro de 45 mm ou 50 mm e rela\u00e7\u00e3o L\/D de 22:1, permitindo a inje\u00e7\u00e3o de materiais com peso entre 260 g e 383 g. O cilindro aquecido de tr\u00eas zonas, com controle de temperatura multissegmentado, garante a plastifica\u00e7\u00e3o completa e homog\u00eanea de HDPE, PP, PS, ABS, PCTG e outras resinas de engenharia antes de cada inje\u00e7\u00e3o, mantendo a consist\u00eancia da massa fundida, essencial para a qualidade da pr\u00e9-forma.<\/p>\n<p>2. Sistema de canais quentes<br \/>\nO sistema de canais quentes otimizado controla com precis\u00e3o a temperatura de fus\u00e3o, o equil\u00edbrio do fluxo e a distribui\u00e7\u00e3o de press\u00e3o em todas as cavidades. Isso garante uma varia\u00e7\u00e3o m\u00ednima no peso em gramas e na espessura da parede entre as cavidades, eliminando a necessidade de canais frios e todo o desperd\u00edcio de material reciclado. O design do coletor balanceado de canais quentes acomoda at\u00e9 14 cavidades para garrafas de pequeno volume, mantendo a qualidade do ponto de inje\u00e7\u00e3o e o tempo de ciclo.<\/p>\n<p>3. Haste central (mandril)<br \/>\nO mandril ou haste central, com engenharia especial, \u00e9 o elemento de transfer\u00eancia principal que transporta a pr\u00e9-forma da inje\u00e7\u00e3o para o sopro e, em seguida, para as esta\u00e7\u00f5es de desmoldagem. Seus canais de resfriamento internos permitem uma queda de temperatura r\u00e1pida e uniforme na parede da pr\u00e9-forma antes do sopro, o que \u00e9 essencial para obter uma distribui\u00e7\u00e3o consistente da espessura da parede. O design do mandril mant\u00e9m ciclos de moldagem r\u00e1pidos, garantindo ao mesmo tempo um excelente efeito de resfriamento do n\u00facleo e uma longa vida \u00fatil sob ciclos t\u00e9rmicos repetidos.<\/p>\n<p>4. Pr\u00e9-forma de garrafa<br \/>\nA pr\u00e9-forma produzida na esta\u00e7\u00e3o de inje\u00e7\u00e3o \u00e9 a forma intermedi\u00e1ria da garrafa final, com a rosca do gargalo j\u00e1 totalmente moldada e precisa. Como as dimens\u00f5es do gargalo s\u00e3o definidas na fase de inje\u00e7\u00e3o e nunca submetidas \u00e0 press\u00e3o do sopro, a precis\u00e3o da rosca e o desempenho da veda\u00e7\u00e3o s\u00e3o inerentemente superiores \u00e0s alternativas de extrus\u00e3o-sopro. O peso em gramas da pr\u00e9-forma e a distribui\u00e7\u00e3o da espessura da parede determinam diretamente a qualidade final da garrafa, e o sistema de inje\u00e7\u00e3o servo ZQ60 mant\u00e9m ambos com excepcional consist\u00eancia.<\/p>\n<p>5. Molde de Inje\u00e7\u00e3o<br \/>\nFabricado com liga de a\u00e7o S136 importada ou a\u00e7o inoxid\u00e1vel de alta resist\u00eancia 4Cr13, o molde de inje\u00e7\u00e3o apresenta insertos de cavidade ajust\u00e1veis \u200b\u200bindependentemente e insertos de gargalo projetados com precis\u00e3o. O design com canal de \u00f3leo permite trocas de insertos r\u00e1pidas e convenientes para acomodar diferentes especifica\u00e7\u00f5es de garrafas sem a necessidade de substitui\u00e7\u00e3o completa do molde. A constru\u00e7\u00e3o em a\u00e7o de alta qualidade prolonga a vida \u00fatil do molde, reduzindo o custo total de propriedade para longas produ\u00e7\u00f5es nesta plataforma de m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro de PET.<\/p>\n<p>6. Posto de Inje\u00e7\u00e3o<br \/>\nNa esta\u00e7\u00e3o de inje\u00e7\u00e3o, a for\u00e7a de fechamento de 600 kN fixa firmemente o molde de inje\u00e7\u00e3o enquanto a rosca avan\u00e7a com velocidade e press\u00e3o servo-controladas para preencher as cavidades. O controle de temperatura em n\u00edvel de esta\u00e7\u00e3o, realizado por meio de m\u00faltiplas zonas no cilindro e circuitos de resfriamento do molde, garante que a pr\u00e9-forma saia na temperatura ideal para a moldagem por sopro imediata. O curso de abertura de 140 mm proporciona espa\u00e7o suficiente para que a mesa rotativa se mova suavemente, sem interfer\u00eancia mec\u00e2nica.<\/p>\n<p>7. Esta\u00e7\u00e3o de Sopro<br \/>\nNa esta\u00e7\u00e3o de sopro, a garra de 100 kN fixa o molde enquanto ar comprimido a 0,7 a 1,2 MPa \u00e9 introduzido atrav\u00e9s do mandril para expandir a pr\u00e9-forma contra as paredes da cavidade. O gerenciamento de resfriamento em n\u00edvel de esta\u00e7\u00e3o garante r\u00e1pida dissipa\u00e7\u00e3o t\u00e9rmica das paredes da garrafa, possibilitando o curto tempo de ciclo de 8,2 segundos alcan\u00e7\u00e1vel com a ZQ60 na produ\u00e7\u00e3o de garrafas de 30 ml. A superf\u00edcie polida da cavidade do molde de sopro proporciona excelente transpar\u00eancia e acabamento superficial \u00e0 garrafa, sem necessidade de opera\u00e7\u00f5es secund\u00e1rias.<\/p>\n<p>8. Moldagem por sopro<br \/>\nO molde de sopro define a geometria externa final da garrafa. Fabricado com usinagem CNC de precis\u00e3o e toler\u00e2ncias rigorosas, possui canais de resfriamento integrados para remover rapidamente o calor da parede da garrafa soprada, permitindo ciclos de produ\u00e7\u00e3o r\u00e1pidos. Com dimens\u00f5es m\u00e1ximas da plataforma de 600 x 390 mm e espessura do molde de 240 mm, a esta\u00e7\u00e3o de sopro ZQ60 acomoda garrafas de at\u00e9 120 mm de di\u00e2metro e 220 mm de altura, abrangendo uma ampla gama de formatos de embalagens padr\u00e3o para aplica\u00e7\u00f5es farmac\u00eauticas, cosm\u00e9ticas e de bebidas.<\/p>\n<p>9. Esta\u00e7\u00e3o de striptease<br \/>\nO curso de extra\u00e7\u00e3o de 230 mm nesta esta\u00e7\u00e3o ejeta suavemente as garrafas resfriadas e acabadas das hastes centrais, sem marcas ou deforma\u00e7\u00f5es na superf\u00edcie. Uma esteira transportadora automatizada recebe as garrafas ejetadas e as transporta diretamente para os equipamentos de inspe\u00e7\u00e3o ou embalagem subsequentes. A a\u00e7\u00e3o de extra\u00e7\u00e3o \u00e9 servo-sincronizada com a inje\u00e7\u00e3o e o sopro para ocorrerem simultaneamente, mantendo o ciclo de trabalho cont\u00ednuo da m\u00e1quina e eliminando o tempo ocioso entre as esta\u00e7\u00f5es, que de outra forma reduziria a capacidade de produ\u00e7\u00e3o geral.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-7452 size-full\" src=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Injection-Blow-Molding-Machine-Operating-Principle-1.webp\" alt=\"Princ\u00edpio de funcionamento da m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro\" width=\"1400\" height=\"920\" srcset=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Injection-Blow-Molding-Machine-Operating-Principle-1.webp 1400w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Injection-Blow-Molding-Machine-Operating-Principle-1-1280x841.webp 1280w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Injection-Blow-Molding-Machine-Operating-Principle-1-980x644.webp 980w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Injection-Blow-Molding-Machine-Operating-Principle-1-480x315.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 1400px, 100vw\" \/><\/p>\n<h2>Mat\u00e9rias-primas compat\u00edveis com a m\u00e1quina IBM ZQ60<\/h2>\n<p>PEAD (Polietileno de Alta Densidade)<br \/>\nO HDPE, material mais utilizado na plataforma ZQ60, oferece excelente resist\u00eancia qu\u00edmica, rigidez e estabilidade aos raios UV. \u00c9 a resina preferida para frascos farmac\u00eauticos, recipientes para produtos qu\u00edmicos e garrafas de leite\/bebidas. O HDPE \u00e9 processado de forma limpa no sistema de inje\u00e7\u00e3o ZQ60, apresentando excelentes caracter\u00edsticas de fluidez e ciclos de produ\u00e7\u00e3o r\u00e1pidos devido ao seu perfil de resfriamento veloz.<\/p>\n<p>PEBD (Polietileno de Baixa Densidade)<br \/>\nA flexibilidade e a maciez do LDPE o tornam ideal para frascos de compress\u00e3o, como conta-gotas, frascos de spray nasal e pequenos recipientes dispensadores. No modelo ZQ60, a baixa viscosidade do LDPE fundido \u00e9 controlada por meio da otimiza\u00e7\u00e3o da velocidade da rosca e da temperatura, proporcionando uma distribui\u00e7\u00e3o uniforme da espessura da parede em aplica\u00e7\u00f5es com paredes finas, sem marcas de afundamento ou defeitos na linha de solda.<\/p>\n<p>PP (Polipropileno)<br \/>\nO polipropileno oferece um equil\u00edbrio entre rigidez, resist\u00eancia ao calor e transpar\u00eancia, ideal para embalagens de cosm\u00e9ticos, frascos de condimentos e aplica\u00e7\u00f5es de envase a quente. A alta temperatura de processamento do PP exige um controle preciso da temperatura nas zonas do cilindro da ZQ60, o que o sistema de aquecimento multizona gerencia com confiabilidade. Os frascos de PP produzidos nesta m\u00e1quina apresentam excelente transpar\u00eancia em copol\u00edmeros e desempenho superior da dobradi\u00e7a para aplica\u00e7\u00f5es de dispensa\u00e7\u00e3o.<\/p>\n<p>PS e PS de Alta Transpar\u00eancia<br \/>\nA ZQ60 processa PS padr\u00e3o e GPPS cristalino para produzir frascos para bact\u00e9rias l\u00e1cticas, potes para iogurte e recipientes transparentes para bebidas. O PS de alta transpar\u00eancia oferece uma clareza \u00f3ptica semelhante \u00e0 do vidro, que diferencia embalagens premium em ambientes de varejo. A velocidade de inje\u00e7\u00e3o servo-controlada da m\u00e1quina garante o preenchimento perfeito das cavidades, essencial para recipientes de PS transparentes de paredes finas.<\/p>\n<p>ABS (Acrilonitrila Butadieno Estireno)<br \/>\nO ABS \u00e9 a escolha ideal para embalagens cosm\u00e9ticas premium, onde s\u00e3o necess\u00e1rios alto brilho superficial, rigidez estrutural e resist\u00eancia a impactos. O processamento do ABS na ZQ60 exige temperaturas ligeiramente mais elevadas no cilindro e um controle preciso da contrapress\u00e3o da rosca para manter a homogeneidade da massa fundida. O resultado s\u00e3o frascos cosm\u00e9ticos com excelente qualidade de superf\u00edcie, adequados para acabamento metalizado e revestimento UV em aplica\u00e7\u00f5es de beleza de luxo.<\/p>\n<p>PCTG e EVA<br \/>\nO PCTG oferece transpar\u00eancia semelhante \u00e0 do PET sem a necessidade de secagem, sendo facilmente processado na ZQ60 para garrafas de bebidas premium, embalagens de cosm\u00e9ticos e recipientes para bebidas saud\u00e1veis. O EVA (etileno vinil acetato) \u00e9 utilizado em aplica\u00e7\u00f5es de compress\u00e3o suave que exigem excelente flexibilidade e resili\u00eancia em baixas temperaturas. Ambas as resinas se beneficiam do controle de temperatura multizona do cilindro da ZQ60 e da precis\u00e3o de inje\u00e7\u00e3o servo para uma produ\u00e7\u00e3o sem defeitos.<\/p>\n<p>Material de milho ambiental (\u00e0 base de PLA)<br \/>\nMateriais biodegrad\u00e1veis \u200b\u200b\u00e0 base de milho e misturas de PLA s\u00e3o cada vez mais procurados por marcas com compromissos de sustentabilidade. O sistema de inje\u00e7\u00e3o com controle de temperatura e a precis\u00e3o servo da ZQ60 s\u00e3o ideais para o processamento de resinas de biopol\u00edmeros sens\u00edveis ao calor. Isso torna a m\u00e1quina uma plataforma avan\u00e7ada para inova\u00e7\u00e3o em embalagens ecol\u00f3gicas, auxiliando fabricantes que buscam certifica\u00e7\u00e3o verde para embalagens de produtos cosm\u00e9ticos, aliment\u00edcios e de sa\u00fade.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-7532 size-full\" src=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-4.webp\" alt=\"M\u00e1quina de Moldagem por Inje\u00e7\u00e3o e Sopro ZQ60\" width=\"1200\" height=\"1200\" srcset=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-4.webp 1200w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-4-980x980.webp 980w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-4-480x480.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1200px, 100vw\" \/><\/p>\n<h2>Caracter\u00edsticas do molde autom\u00e1tico da s\u00e9rie ZQ<\/h2>\n<div>\n<h3>1. Projeto de Cavidade Modular<\/h3>\n<p>O molde de inje\u00e7\u00e3o apresenta insertos de cavidade e de gargalo projetados independentemente e ajust\u00e1veis, com uma configura\u00e7\u00e3o de canal de \u00f3leo especialmente desenvolvida que permite a troca r\u00e1pida de componentes sem a necessidade de remo\u00e7\u00e3o completa da ferramenta. Essa arquitetura modular garante dimens\u00f5es est\u00e1veis \u200b\u200bdo tarugo tubular pr\u00e9-formado e distribui\u00e7\u00e3o uniforme de temperatura em todas as cavidades, fatores cr\u00edticos para manter a consist\u00eancia do peso em gramas e da espessura da parede desde a primeira inje\u00e7\u00e3o at\u00e9 a milion\u00e9sima.<\/p>\n<\/div>\n<div>\n<h3>2. Constru\u00e7\u00e3o em liga de a\u00e7o premium<\/h3>\n<p>As cavidades dos moldes s\u00e3o fabricadas em a\u00e7o liga S136 importado ou a\u00e7o inoxid\u00e1vel 4Cr13, materiais selecionados por sua dureza superior, resist\u00eancia \u00e0 corros\u00e3o e capacidade de polimento. O a\u00e7o S136, em particular, proporciona um acabamento superficial espelhado, ideal para embalagens transparentes de alta clareza, enquanto o a\u00e7o inoxid\u00e1vel 4Cr13 oferece excelente resist\u00eancia \u00e0 umidade e a agentes de limpeza. A constru\u00e7\u00e3o em a\u00e7o de alta resist\u00eancia prolonga a vida \u00fatil do molde muito al\u00e9m da dos a\u00e7os-ferramenta padr\u00e3o, reduzindo o custo total de ferramental por milh\u00e3o de unidades produzidas.<\/p>\n<\/div>\n<div>\n<h3>3. Sistema otimizado de canais quentes e mandril<\/h3>\n<p>O sistema de canais quentes e a geometria do mandril s\u00e3o otimizados em conjunto para minimizar a varia\u00e7\u00e3o de peso e a espessura da parede em cada cavidade. A estrutura de resfriamento interno especializada do mandril proporciona uma extra\u00e7\u00e3o de calor r\u00e1pida e uniforme durante o ciclo de sopro, permitindo um ciclo de 8,2 segundos para garrafas de 30 ml sem comprometer a qualidade. Esse equil\u00edbrio entre ciclo r\u00e1pido e excelente resfriamento do n\u00facleo \u00e9 uma marca registrada da expertise da CMN na fabrica\u00e7\u00e3o de m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro.<\/p>\n<\/div>\n<div>\n<h3>4. Rosca de Precis\u00e3o e Veda\u00e7\u00e3o 100%<\/h3>\n<p>As dimens\u00f5es da rosca da boca da garrafa s\u00e3o mantidas dentro de toler\u00e2ncias rigorosas em cada ciclo de inje\u00e7\u00e3o, garantindo dimens\u00f5es precisas e integridade da veda\u00e7\u00e3o 100% com sistemas de fechamento padr\u00e3o. O formato da rosca e a superf\u00edcie de veda\u00e7\u00e3o s\u00e3o criados na esta\u00e7\u00e3o de inje\u00e7\u00e3o, onde a press\u00e3o do metal fundido e o controle do a\u00e7o do molde moldam a geometria com precis\u00e3o, e n\u00e3o na esta\u00e7\u00e3o de sopro, onde o controle dimensional seria menos preciso. Isso garante que todas as garrafas produzidas passem nos testes de aplica\u00e7\u00e3o da tampa e de vazamento sem necessidade de ajustes manuais.<\/p>\n<\/div>\n<div>\n<h3>5. Zero Flash, Zero Rebarbas<\/h3>\n<p>As linhas de separa\u00e7\u00e3o e a geometria de inje\u00e7\u00e3o com lapida\u00e7\u00e3o de precis\u00e3o dos moldes da S\u00e9rie ZQ da CMN produzem garrafas sem rebarbas na boca, sem rebarbas no fundo e sem linhas de refer\u00eancia que exijam aparamento. Essa caracter\u00edstica de produ\u00e7\u00e3o sem aparamento elimina opera\u00e7\u00f5es de acabamento secund\u00e1rias, reduz a necessidade de m\u00e3o de obra e garante que todas as superf\u00edcies das garrafas atendam aos padr\u00f5es de qualidade est\u00e9tica diretamente da m\u00e1quina, tornando a ZQ60 uma verdadeira solu\u00e7\u00e3o para eliminar rebarbas em m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro.<\/p>\n<\/div>\n<div>\n<h3>6. Consist\u00eancia dimensional completa em todas as cavidades<\/h3>\n<p>O tamanho, o peso, a posi\u00e7\u00e3o da linha de parti\u00e7\u00e3o e a espessura da parede do produto s\u00e3o consistentes em todas as cavidades em cada ciclo, verificados por meio de medi\u00e7\u00f5es de precis\u00e3o CMN e an\u00e1lise da capacidade do processo durante a qualifica\u00e7\u00e3o do molde. A varia\u00e7\u00e3o de peso entre as cavidades \u00e9 minimizada por meio de um projeto balanceado do coletor de canais quentes e taxas de resfriamento do mandril correspondentes. Essa consist\u00eancia \u00e9 o que permite que o ZQ60 alimente linhas de envase automatizadas e sistemas de inspe\u00e7\u00e3o que rejeitam produtos com base em n\u00e3o conformidades dimensionais.<\/p>\n<\/div>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-7516 size-full\" src=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ-Series-Injection-Blow-Molding-Machine-Mould-4.webp\" alt=\"M\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro da s\u00e9rie ZQ\" width=\"1570\" height=\"1053\" srcset=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ-Series-Injection-Blow-Molding-Machine-Mould-4.webp 1570w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ-Series-Injection-Blow-Molding-Machine-Mould-4-1280x858.webp 1280w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ-Series-Injection-Blow-Molding-Machine-Mould-4-980x657.webp 980w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ-Series-Injection-Blow-Molding-Machine-Mould-4-480x322.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 1570px, 100vw\" \/><\/p>\n<h2>Solu\u00e7\u00e3o de problemas comuns<\/h2>\n<p>1. Espessura de parede irregular nas cavidades<br \/>\nSintoma: as medi\u00e7\u00f5es da espessura da parede de uma cavidade diferem significativamente das cavidades adjacentes. As causas principais incluem zonas de temperatura desequilibradas no coletor de canais quentes, linhas centrais do mandril desgastadas ou desalinhadas, taxas de fluxo de \u00e1gua de resfriamento desiguais nas zonas do molde ou varia\u00e7\u00e3o da press\u00e3o de inje\u00e7\u00e3o entre os ciclos. A\u00e7\u00f5es corretivas: verificar as temperaturas das zonas de canais quentes em rela\u00e7\u00e3o ao ponto de ajuste, medir o desvio radial do mandril e realinh\u00e1-lo, equilibrar o fluxo de resfriamento com medidores de fluxo e revisar os perfis de velocidade e press\u00e3o de inje\u00e7\u00e3o no controlador da m\u00e1quina em busca de desvios.<\/p>\n<p>2. Inje\u00e7\u00e3o incompleta ou enchimento incompleto da pr\u00e9-forma<br \/>\nSintoma: as pr\u00e9-formas saem da esta\u00e7\u00e3o de inje\u00e7\u00e3o com material faltante, vazios vis\u00edveis ou forma\u00e7\u00e3o incompleta do gargalo. As causas prov\u00e1veis \u200b\u200bs\u00e3o temperatura de fus\u00e3o insuficiente, velocidade de inje\u00e7\u00e3o inadequada, configura\u00e7\u00e3o de contrapress\u00e3o baixa, resina degradada ou contaminada ou um canal de inje\u00e7\u00e3o parcialmente obstru\u00eddo. Medidas corretivas: aumentar a temperatura da zona do cilindro em incrementos de 5 a 10 \u00b0C, verificar o perfil de velocidade de inje\u00e7\u00e3o, aumentar a contrapress\u00e3o para melhorar a homogeneidade da massa fundida, verificar o teor de umidade da resina e sec\u00e1-la adequadamente, se necess\u00e1rio, e inspecionar os canais de inje\u00e7\u00e3o em busca de dep\u00f3sitos de carbono.<\/p>\n<p>3. Deforma\u00e7\u00e3o do gargalo da garrafa ap\u00f3s a remo\u00e7\u00e3o do lacre.<br \/>\nSintoma: o gargalo das garrafas fica oval ou deformado ap\u00f3s a eje\u00e7\u00e3o da esta\u00e7\u00e3o de extra\u00e7\u00e3o, apesar das dimens\u00f5es corretas do molde de inje\u00e7\u00e3o. A causa geralmente \u00e9 o tempo de resfriamento insuficiente no molde de inje\u00e7\u00e3o, resultando em material do gargalo ainda macio no momento da extra\u00e7\u00e3o. Verifique tamb\u00e9m o alinhamento do curso de extra\u00e7\u00e3o e certifique-se de que a temperatura da barra fria na esta\u00e7\u00e3o de extra\u00e7\u00e3o esteja dentro da especifica\u00e7\u00e3o. Aumente o tempo de resfriamento da inje\u00e7\u00e3o em incrementos de 0,5 segundo at\u00e9 que a deforma\u00e7\u00e3o do gargalo seja eliminada, sem exceder o tempo de ciclo previsto.<\/p>\n<p>4. Opacidade superficial ou falta de transpar\u00eancia em garrafas transparentes<br \/>\nSintoma: Garrafas transparentes de copol\u00edmero de PS, PCTG ou PP saem da m\u00e1quina com uma n\u00e9voa leitosa ou acabamento superficial fosco. As principais causas s\u00e3o temperatura excessiva na cavidade do molde, reduzindo a taxa de resfriamento, umidade em resinas higrosc\u00f3picas (especialmente PCTG), temperatura de fus\u00e3o muito baixa, causando fluxo insuficiente, ou contamina\u00e7\u00e3o da superf\u00edcie do molde. A\u00e7\u00f5es corretivas: reduzir a temperatura da \u00e1gua de resfriamento do molde, pr\u00e9-secar a resina PCTG a 65 \u00b0C por no m\u00ednimo 4 horas, aumentar as temperaturas do cilindro dentro dos limites de especifica\u00e7\u00e3o da resina e polir as superf\u00edcies afetadas da cavidade.<\/p>\n<p>5. Estouro de bolha de sab\u00e3o ou expans\u00e3o irregular do ar soprado<br \/>\nSintoma: a pr\u00e9-forma estoura ou rasga durante a etapa de sopro, ou a parede da garrafa n\u00e3o se expande uniformemente contra a cavidade do molde de sopro. As principais causas incluem press\u00e3o de ar de sopro muito alta, pr\u00e9-forma muito quente na entrada da esta\u00e7\u00e3o de sopro, resfriamento insuficiente do mandril resultando em uma parede da pr\u00e9-forma mole, ou sincroniza\u00e7\u00e3o do sopro desalinhada com a faixa de temperatura da pr\u00e9-forma. Reduza a press\u00e3o de sopro em incrementos de 0,05 MPa, aumente o tempo de resfriamento do mandril, verifique a temperatura da \u00e1gua de resfriamento na esta\u00e7\u00e3o de sopro e verifique a sequ\u00eancia de indexa\u00e7\u00e3o no programa da m\u00e1quina.<\/p>\n<p>6. Varia\u00e7\u00e3o inconsistente do peso da garrafa ao longo do tempo<br \/>\nSintoma: o peso m\u00e9dio das garrafas oscila para cima ou para baixo durante a produ\u00e7\u00e3o, apesar das configura\u00e7\u00f5es est\u00e1veis \u200b\u200bdo controlador. As causas comuns s\u00e3o inconsist\u00eancia no fornecimento de resina (varia\u00e7\u00e3o do MFI entre lotes), degrada\u00e7\u00e3o gradual do aquecedor do canal quente causando oscila\u00e7\u00e3o de temperatura, desgaste do anel de reten\u00e7\u00e3o da rosca permitindo varia\u00e7\u00e3o no tamanho da inje\u00e7\u00e3o ou varia\u00e7\u00e3o da temperatura da \u00e1gua de resfriamento entre os turnos. A\u00e7\u00f5es corretivas: verificar o MFI da resina recebida em rela\u00e7\u00e3o \u00e0 especifica\u00e7\u00e3o, auditar os controladores de temperatura do canal quente, inspecionar a ponta da rosca e o anel de reten\u00e7\u00e3o quanto a desgaste e confirmar se a temperatura da \u00e1gua da torre de resfriamento est\u00e1 est\u00e1vel durante os per\u00edodos de produ\u00e7\u00e3o.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-7531 size-full\" src=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-3.webp\" alt=\"M\u00e1quina de Moldagem por Inje\u00e7\u00e3o e Sopro ZQ60\" width=\"1200\" height=\"1200\" srcset=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-3.webp 1200w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-3-980x980.webp 980w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-3-480x480.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1200px, 100vw\" \/><\/p>\n<h2>Por que escolher a m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro da CMN?<\/h2>\n<p>A CMN Transmission \u00e9 uma fabricante especializada em m\u00e1quinas autom\u00e1ticas de moldagem por inje\u00e7\u00e3o e sopro em uma \u00fanica etapa e em moldes para essas m\u00e1quinas, com comprovada atua\u00e7\u00e3o global nos setores farmac\u00eautico, cosm\u00e9tico, aliment\u00edcio e de embalagens qu\u00edmicas. A CMN fabrica m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro, m\u00e1quinas de moldagem por extrus\u00e3o e sopro, m\u00e1quinas de moldagem por inje\u00e7\u00e3o e estiramento e equipamentos auxiliares, abrangendo produ\u00e7\u00f5es de 1 ml a 1000 ml com todas as principais resinas termopl\u00e1sticas. Nossas s\u00e9ries ZQ40, ZQ60, ZQ80, ZQ110 e ZQ135 atendem a todas as escalas de produ\u00e7\u00e3o, desde pequenos lotes de cosm\u00e9ticos at\u00e9 grandes opera\u00e7\u00f5es farmac\u00eauticas.<\/p>\n<p><strong>1. Solu\u00e7\u00f5es completas \"chave na m\u00e3o\"<\/strong><br \/>\nA CMN constr\u00f3i linhas de produ\u00e7\u00e3o completas e integradas, combinando a m\u00e1quina, o molde da S\u00e9rie ZQ, transportadores subsequentes, sistemas de inspe\u00e7\u00e3o e equipamentos de rotulagem. Nossa equipe de engenharia gerencia todo o projeto, desde a verifica\u00e7\u00e3o do design da garrafa at\u00e9 os testes de aceita\u00e7\u00e3o em f\u00e1brica, oferecendo aos clientes um \u00fanico ponto de contato para todo o sistema de produ\u00e7\u00e3o, em vez de coordenar v\u00e1rios fornecedores.<\/p>\n<p><strong>2. Equipe de Engenharia de P&amp;D Especializada<\/strong><br \/>\nNossa equipe multidisciplinar de P&amp;D inclui engenheiros mec\u00e2nicos, especialistas em design de moldes e especialistas em processamento de pl\u00e1sticos com vasta experi\u00eancia no desenvolvimento de m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro. O investimento cont\u00ednuo em inova\u00e7\u00e3o de produtos resultou na estrutura de fechamento pressurizado exclusiva da ZQ60 e em um design higi\u00eanico de baixo para cima. Oferecemos an\u00e1lise de viabilidade do design da garrafa antes da venda e consultoria t\u00e9cnica detalhada sem custo adicional para compradores interessados.<\/p>\n<p><strong>3. Rede Global de P\u00f3s-Venda<\/strong><br \/>\nCom agentes e equipes de instala\u00e7\u00e3o estabelecidas na Coreia, \u00cdndia, Turquia, R\u00fassia, \u00c1frica do Sul, Brasil, EUA e M\u00e9xico, a CMN oferece comissionamento e treinamento no local, independentemente da localiza\u00e7\u00e3o da sua f\u00e1brica. Suporte remoto via videochamada e monitoramento de dados da m\u00e1quina est\u00e3o dispon\u00edveis 24 horas por dia, 7 dias por semana, para problemas urgentes. As pe\u00e7as de reposi\u00e7\u00e3o s\u00e3o mantidas em estoque na f\u00e1brica da CMN para envio no mesmo dia, minimizando o tempo de inatividade da produ\u00e7\u00e3o em nossa base global de clientes usu\u00e1rios de m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro.<\/p>\n<p><strong>4. Conformidade total com as normas do setor<\/strong><br \/>\nAs m\u00e1quinas CMN s\u00e3o constru\u00eddas em conformidade com as normas internacionais de seguran\u00e7a e qualidade aplic\u00e1veis. O design higi\u00eanico do modelo ZQ60 e o sistema de servoacionamento isento de \u00f3leo est\u00e3o alinhados com os requisitos das Boas Pr\u00e1ticas de Fabrica\u00e7\u00e3o (BPF) para a produ\u00e7\u00e3o de embalagens farmac\u00eauticas. A documenta\u00e7\u00e3o CE e a conformidade com as normas GOST est\u00e3o dispon\u00edveis para os mercados europeu e da CEI. Todos os sistemas el\u00e9tricos atendem aos padr\u00f5es internacionais de seguran\u00e7a para m\u00e1quinas industriais, facilitando os processos de desembara\u00e7o aduaneiro e aprova\u00e7\u00e3o de seguran\u00e7a em mercados regulamentados em todo o mundo.<\/p>\n<p><strong>5. Valores da Empresa e Parcerias de Longo Prazo<\/strong><br \/>\nA CMN Transmission adere aos princ\u00edpios de desenvolvimento empresarial de autossufici\u00eancia, integridade, pragmatismo, inova\u00e7\u00e3o e responsabilidade. Constru\u00edmos relacionamentos de longo prazo com nossos fornecedores, n\u00e3o apenas transa\u00e7\u00f5es pontuais. Nossa taxa de recompra entre os fornecedores de m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro em nossa categoria reflete a confian\u00e7a do cliente, constru\u00edda ao longo de anos de desempenho confi\u00e1vel das m\u00e1quinas, comunica\u00e7\u00e3o transparente e suporte p\u00f3s-venda \u00e1gil. Convidamos voc\u00ea a solicitar refer\u00eancias de clientes existentes em sua regi\u00e3o.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-7536 size-full\" src=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Injection-Blow-Molding-Machine-Manufacturers.webp\" alt=\"\" width=\"1832\" height=\"1452\" srcset=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Injection-Blow-Molding-Machine-Manufacturers.webp 1832w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Injection-Blow-Molding-Machine-Manufacturers-1280x1014.webp 1280w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Injection-Blow-Molding-Machine-Manufacturers-980x777.webp 980w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/Injection-Blow-Molding-Machine-Manufacturers-480x380.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 1832px, 100vw\" \/><\/p>\n<h2>Perguntas frequentes<\/h2>\n<p><strong>P: Qual \u00e9 o pre\u00e7o da m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro ZQ60?<\/strong><br \/>\nR: O pre\u00e7o de m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro, como a ZQ60, depende da configura\u00e7\u00e3o do molde, da especifica\u00e7\u00e3o do material e dos pacotes de automa\u00e7\u00e3o opcionais. A CMN fornece or\u00e7amentos personalizados com base nas suas necessidades espec\u00edficas de produ\u00e7\u00e3o. A ZQ60 oferece desempenho com qualidade europeia a um custo significativamente menor do que m\u00e1quinas compar\u00e1veis \u200b\u200bda AOKI ou Jomar, tornando-se uma excelente op\u00e7\u00e3o para fabricantes que buscam m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro com pre\u00e7os competitivos, sem abrir m\u00e3o das especifica\u00e7\u00f5es t\u00e9cnicas. Entre em contato conosco com as especifica\u00e7\u00f5es da sua garrafa para receber um or\u00e7amento formal.<\/p>\n<p><strong>P: Quais materiais a m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro de pl\u00e1stico ZQ60 pode processar?<\/strong><br \/>\nA: A m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro de pl\u00e1stico ZQ60 \u00e9 compat\u00edvel com HDPE, LDPE, PP, PS, PS de alta transpar\u00eancia, ABS, PCTG, EVA e materiais biodegrad\u00e1veis \u200b\u200b\u00e0 base de milho. Ela abrange todo o espectro de resinas utilizadas na fabrica\u00e7\u00e3o de embalagens para os setores farmac\u00eautico, cosm\u00e9tico, de bebidas e qu\u00edmico, com volumes de 1 ml a 1000 ml. O controle de temperatura do cilindro em m\u00faltiplas zonas e o sistema de inje\u00e7\u00e3o servo lidam de forma confi\u00e1vel com as variadas caracter\u00edsticas de fus\u00e3o dessas resinas. Para resinas especiais, como materiais de barreira EVOH, consulte a equipe de engenharia da CMN para uma avalia\u00e7\u00e3o da viabilidade do processo.<\/p>\n<p><strong>P: Como a ZQ60 se compara como substituta da m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro da AOKI?<\/strong><br \/>\nA: A ZQ60 \u00e9 uma substituta funcional direta dos modelos de m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro da Aoki na mesma faixa de tonelagem. Ela atende ou supera as especifica\u00e7\u00f5es da Aoki em for\u00e7a de fechamento (inje\u00e7\u00e3o de 600 kN), tempo de ciclo (8,2 s a 30 ml) e capacidade de produ\u00e7\u00e3o (105.000 garrafas\/dia). A ZQ60 tem um pre\u00e7o de aquisi\u00e7\u00e3o significativamente menor, oferecendo um sistema de servoacionamento completo compar\u00e1vel \u00e0 s\u00e9rie el\u00e9trica da Aoki. A CMN oferece consultoria em adapta\u00e7\u00e3o de moldes para usu\u00e1rios que migram ferramentas existentes compat\u00edveis com a Aoki para a plataforma ZQ60. Muitos clientes na Coreia, Turquia e EUA j\u00e1 realizaram essa transi\u00e7\u00e3o com sucesso.<\/p>\n<p><strong>P: Qual a diferen\u00e7a entre uma m\u00e1quina IBM e uma m\u00e1quina ISBM?<\/strong><br \/>\nA: Uma m\u00e1quina IBM (m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro), como a ZQ60, produz garrafas em um \u00fanico est\u00e1gio, injetando uma pr\u00e9-forma e soprando-a imediatamente at\u00e9 atingir o formato final, ainda presa \u00e0 haste de moldagem, sem necessidade de reaquecimento. Uma m\u00e1quina ISBM (m\u00e1quina de moldagem por inje\u00e7\u00e3o e estiramento e sopro) adiciona uma haste de estiramento que alonga fisicamente a pr\u00e9-forma axialmente antes da aplica\u00e7\u00e3o do ar comprimido, produzindo garrafas com orienta\u00e7\u00e3o biaxial, maior transpar\u00eancia, melhores propriedades de barreira e maior resist\u00eancia a impactos. A ZQ60 \u00e9 um projeto da IBM; a CMN tamb\u00e9m fabrica modelos de m\u00e1quinas de moldagem por inje\u00e7\u00e3o e estiramento e sopro para aplica\u00e7\u00f5es que exigem orienta\u00e7\u00e3o biaxial, como garrafas de refrigerantes.<\/p>\n<p><strong>P: A ZQ60 pode ser personalizada como uma m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro de est\u00e1gio \u00fanico?<\/strong><br \/>\nA: A ZQ60 padr\u00e3o \u00e9 uma plataforma de moldagem por inje\u00e7\u00e3o e sopro. Para aplica\u00e7\u00f5es que exigem orienta\u00e7\u00e3o biaxial, como garrafas de bebidas transparentes em PET ou PP com propriedades de barreira aprimoradas, a CMN oferece a ZQ60HE e modelos dedicados de m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro de est\u00e1gio \u00fanico com mecanismos de haste de estiramento integrados. A equipe de engenharia da CMN pode avaliar se o design da sua garrafa e a sele\u00e7\u00e3o de materiais s\u00e3o melhor atendidos pelo processo IBM ou ISBM e recomendar a configura\u00e7\u00e3o de m\u00e1quina apropriada. Op\u00e7\u00f5es de m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro personalizadas est\u00e3o dispon\u00edveis para geometrias de garrafa especializadas.<\/p>\n<p><strong>P: Qual \u00e9 o tempo de ciclo da m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro totalmente el\u00e9trica ZQ60 para diferentes tamanhos de garrafa?<\/strong><br \/>\nR: Para garrafas de 30 ml, a m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro totalmente el\u00e9trica ZQ60 atinge um tempo de ciclo de 8,2 segundos, produzindo 105.000 garrafas por dia em configura\u00e7\u00f5es de produ\u00e7\u00e3o padr\u00e3o. Para garrafas maiores, o tempo de ciclo aumenta com o peso e a espessura da parede: garrafas de 60 ml geralmente levam de 9 a 11 segundos para o ciclo, de 100 ml de 11 a 14 segundos, de 250 ml de 14 a 18 segundos e de 500 ml a 1000 ml de 18 a 28 segundos, dependendo da espessura da parede e do tipo de resina. O tempo de secagem \u00e9 de 4 segundos. A equipe t\u00e9cnica da CMN pode fornecer uma estimativa detalhada do tempo de ciclo para as especifica\u00e7\u00f5es e o material da sua garrafa, mediante solicita\u00e7\u00e3o.<\/p>\n<p><strong>P: Que tipo de servi\u00e7o p\u00f3s-venda os fornecedores de m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro, como a CMN, oferecem?<\/strong><br \/>\nA: A CMN Transmission oferece suporte p\u00f3s-venda completo, incluindo comissionamento de f\u00e1brica e treinamento de operadores, suporte de diagn\u00f3stico remoto via videochamada e compartilhamento de tela, garantia m\u00ednima de um ano para componentes mec\u00e2nicos e el\u00e9tricos, estoque de pe\u00e7as de reposi\u00e7\u00e3o mantido na f\u00e1brica da CMN para envio r\u00e1pido e contratos de servi\u00e7o estendidos opcionais. A CMN estabeleceu redes de agentes no exterior na Coreia, \u00cdndia, Turquia, R\u00fassia, \u00c1frica do Sul, Brasil, EUA e M\u00e9xico para fornecer atendimento local para necessidades de servi\u00e7o urgentes. A documenta\u00e7\u00e3o t\u00e9cnica \u00e9 fornecida em ingl\u00eas e est\u00e1 dispon\u00edvel em outros idiomas mediante solicita\u00e7\u00e3o.<\/p>\n<p><strong>P: Posso conectar a m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro ZQ60 a um sistema de inspe\u00e7\u00e3o visual?<\/strong><br \/>\nR: Sim. A m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro ZQ60 foi projetada com pontos de integra\u00e7\u00e3o de esteira transportadora compat\u00edveis com as principais marcas de sistemas de inspe\u00e7\u00e3o visual. O sistema de inspe\u00e7\u00e3o pode ser configurado para detectar contamina\u00e7\u00e3o por part\u00edculas estranhas dentro da garrafa, quantidade insuficiente de material na boca da garrafa e forma\u00e7\u00e3o irregular do fundo da garrafa. As garrafas rejeitadas s\u00e3o automaticamente desviadas antes de chegarem \u00e0 embalagem. A CMN pode oferecer consultoria sobre as especifica\u00e7\u00f5es do sistema de inspe\u00e7\u00e3o e a fia\u00e7\u00e3o de integra\u00e7\u00e3o durante a fase de or\u00e7amento da m\u00e1quina, possibilitando uma solu\u00e7\u00e3o completa de linha de produ\u00e7\u00e3o automatizada \"chave na m\u00e3o\".<\/p>\n<p><strong>P: Como o ZQ60 est\u00e1 em conformidade com os requisitos de BPF (Boas Pr\u00e1ticas de Fabrica\u00e7\u00e3o) para embalagens farmac\u00eauticas?<\/strong><br \/>\nA: O design estrutural ascendente do ZQ60 impede fisicamente a migra\u00e7\u00e3o do \u00f3leo lubrificante para a cavidade do molde, que \u00e9 o principal risco de contamina\u00e7\u00e3o em m\u00e1quinas convencionais de moldagem por inje\u00e7\u00e3o e sopro para aplica\u00e7\u00f5es farmac\u00eauticas. O sistema de acionamento totalmente servo-assistido elimina completamente o \u00f3leo hidr\u00e1ulico do sistema de movimenta\u00e7\u00e3o da m\u00e1quina. A zona do molde, fechada pela m\u00e1quina, pode ser equipada com compartimentos de press\u00e3o positiva com filtro HEPA para compatibilidade com salas limpas Classe 100.000. Todas as superf\u00edcies em contato com o produto no molde s\u00e3o fabricadas com a\u00e7os em conformidade com as normas da FDA. A CMN oferece suporte completo para a documenta\u00e7\u00e3o de qualifica\u00e7\u00e3o GMP.<\/p>\n<p><strong>P: Qual \u00e9 o prazo de entrega para uma m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro personalizada da CMN?<\/strong><br \/>\nR: As m\u00e1quinas ZQ60 padr\u00e3o geralmente est\u00e3o dispon\u00edveis com um prazo de produ\u00e7\u00e3o e entrega de 60 a 90 dias a partir da confirma\u00e7\u00e3o do pedido e recebimento do dep\u00f3sito. Para configura\u00e7\u00f5es personalizadas de m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro, incluindo especifica\u00e7\u00f5es especiais de moldes, tamanhos de placas n\u00e3o padronizados, integra\u00e7\u00e3o de automa\u00e7\u00e3o adicional ou normas el\u00e9tricas espec\u00edficas (CE, UL, GOST), os prazos de entrega s\u00e3o de 90 a 120 dias. A equipe de gerenciamento de projetos da CMN fornece um cronograma de produ\u00e7\u00e3o detalhado na assinatura do contrato, com atualiza\u00e7\u00f5es semanais de progresso e op\u00e7\u00f5es de inspe\u00e7\u00e3o da f\u00e1brica para clientes que desejam visit\u00e1-la antes do envio.<\/p>\n<p><strong>P: Qual \u00e9 o pedido m\u00ednimo e o tamanho m\u00ednimo de garrafa que a m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro ZQ60 da IBM pode produzir?<\/strong><br \/>\nA: A m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro ZQ60 da IBM pode produzir garrafas com capacidade m\u00ednima de 10 ml (com at\u00e9 14 cavidades) e m\u00e1xima de 1000 ml (com 2 cavidades). A altura ideal das garrafas varia de 15 mm a 200 mm, e o di\u00e2metro m\u00e1ximo \u00e9 de 120 mm. Para garrafas muito pequenas, com menos de 10 ml, a CMN recomenda consultar o modelo ZQ40, que pode oferecer melhor custo-benef\u00edcio em termos de ferramental para volumes menores. N\u00e3o h\u00e1 restri\u00e7\u00e3o de quantidade m\u00ednima de pedido; a m\u00e1quina pode operar com ciclos curtos de produ\u00e7\u00e3o de forma eficiente, gra\u00e7as ao sistema modular de insertos de moldes que reduz o tempo de troca de formato.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-7529 size-full\" src=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-1.webp\" alt=\"M\u00e1quina de Moldagem por Inje\u00e7\u00e3o e Sopro ZQ60\" width=\"1200\" height=\"1200\" srcset=\"https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-1.webp 1200w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-1-980x980.webp 980w, https:\/\/korea-transmission.com\/wp-content\/uploads\/2026\/07\/ZQ60-Injection-Blow-Molding-Machine-1-480x480.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1200px, 100vw\" \/><\/p>\n<h2>Avalia\u00e7\u00f5es de clientes<\/h2>\n<p><strong>Park Ji-hoon, Gerente de Produ\u00e7\u00e3o, Coreia<\/strong><br \/>\n\u201cEstamos utilizando a ZQ60 em nossa linha de envase de produtos farmac\u00eauticos h\u00e1 cerca de 14 meses, produzindo c\u00e1psulas de HDPE de 100 ml com 8 cavidades. A produ\u00e7\u00e3o gira em torno de 88.000 frascos por dia, o que \u00e9 significativamente melhor do que a antiga m\u00e1quina hidr\u00e1ulica que substitu\u00edmos. O que realmente importa para n\u00f3s \u00e9 a precis\u00e3o da rosca do gargalo \u2013 t\u00ednhamos problemas com rejei\u00e7\u00e3o de tampas na m\u00e1quina antiga e, desde a instala\u00e7\u00e3o da ZQ60, praticamente eliminamos esse problema. O engenheiro da CMN esteve presente para o comissionamento e permaneceu tr\u00eas dias extras para nos ajudar a ajustar as configura\u00e7\u00f5es do processo. Suporte muito profissional.\u201d<\/p>\n<p><strong>Park Ji-hoon, Gerente de Produ\u00e7\u00e3o, Coreia<\/strong><br \/>\n\u201cSinceramente, eu estava um pouco c\u00e9tico em rela\u00e7\u00e3o ao pre\u00e7o da m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro da CMN, comparado a algumas marcas europeias, mas depois de analisar as especifica\u00e7\u00f5es e conversar com a equipe de vendas, decidi experimentar. Seis meses depois, n\u00e3o me arrependo. Produzimos frascos cosm\u00e9ticos de PP de 60 ml com 10 cavidades, e a consist\u00eancia da espessura da parede \u00e9 excelente. Nossa linha de envase subsequente opera com muito mais efici\u00eancia agora, pois n\u00e3o temos mais rejei\u00e7\u00f5es por problemas dimensionais dos frascos. A economia de energia tamb\u00e9m \u00e9 real \u2013 comparei nossas contas de luz e estamos economizando aproximadamente 281 TP3T em compara\u00e7\u00e3o com nossa m\u00e1quina antiga.\u201d<\/p>\n<p><strong>Mehmet Yilmaz, Diretor T\u00e9cnico, Turquia<\/strong><br \/>\n\u201cFabricamos embalagens farmac\u00eauticas e cosm\u00e9ticas em Istambul e escolhemos a ZQ60 para substituir a m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro Aoki que oper\u00e1vamos h\u00e1 muitos anos. A ZQ60 iguala ou supera a Aoki em todos os par\u00e2metros t\u00e9cnicos que medimos. O tempo de ciclo \u00e9 mais r\u00e1pido, o consumo de energia por mil frascos \u00e9 menor e o processo de troca de moldes \u00e9 mais simples. A CMN forneceu documenta\u00e7\u00e3o t\u00e9cnica completa em ingl\u00eas e turco, e o servi\u00e7o de suporte remoto por videochamada tem sido muito eficiente. J\u00e1 encomendamos uma segunda m\u00e1quina ZQ80.\u201d<\/p>\n<p><strong>Dmitri Volkov, Gerente de Opera\u00e7\u00f5es, R\u00fassia<\/strong><br \/>\n\u201cA coordena\u00e7\u00e3o de envio e log\u00edstica da CMN foi excelente. A m\u00e1quina ZQ60 chegou a Moscou dentro do prazo estimado, bem embalada em uma caixa de madeira e sem nenhum dano durante o transporte. A CMN providenciou um t\u00e9cnico que chegou em at\u00e9 duas semanas ap\u00f3s a libera\u00e7\u00e3o alfandeg\u00e1ria da m\u00e1quina para instala\u00e7\u00e3o e treinamento. Produzimos garrafas de bebidas de 350 ml em PS de alta transpar\u00eancia e a m\u00e1quina produz garrafas muito claras, sem qualquer opacidade. A produ\u00e7\u00e3o est\u00e1 pr\u00f3xima de 60.000 unidades por dia em nossas configura\u00e7\u00f5es de ciclo preferidas. O n\u00edvel de ru\u00eddo da m\u00e1quina \u00e9 muito menor do que o esperado, o que nossos operadores apreciam bastante.\u201d<\/p>\n<p><strong>Linda Nkosi, Supervisora \u200b\u200bde Produ\u00e7\u00e3o, \u00c1frica do Sul<\/strong><br \/>\n\u201cOperamos duas m\u00e1quinas ZQ60 em nossa unidade na Cidade do Cabo \u2013 uma para recipientes de HDPE de 300 ml e outra para 1 litro. Ambas est\u00e3o em funcionamento h\u00e1 quase dois anos sem grandes problemas. O suporte p\u00f3s-venda da CMN \u00e9 realmente melhor do que esper\u00e1vamos de um fornecedor chin\u00eas de m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro. Quando tivemos uma falha em um termopar na zona de canais quentes, o engenheiro da CMN diagnosticou o problema remotamente no mesmo dia e a pe\u00e7a de reposi\u00e7\u00e3o chegou por transportadora em uma semana. No geral, estamos muito satisfeitos tanto com o desempenho da m\u00e1quina quanto com o relacionamento p\u00f3s-venda.\u201d<\/p>\n<p><strong>Carlos Andrade, Gerente Geral, Brasil<\/strong><br \/>\n\u201cMinha empresa em S\u00e3o Paulo produz frascos para cosm\u00e9ticos e produtos de higiene pessoal. Escolhemos a ZQ60 ap\u00f3s compararmos diversas m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro de fabricantes da China e da Europa. A m\u00e1quina da CMN apresentou a melhor combina\u00e7\u00e3o de pre\u00e7o e especifica\u00e7\u00f5es t\u00e9cnicas. Estamos utilizando-a h\u00e1 oito meses, produzindo frascos cosm\u00e9ticos de PCTG de 30 ml e 60 ml, e a qualidade tem sido muito consistente. Um ponto que gostaria de mencionar \u00e9 que o manual de instala\u00e7\u00e3o e treinamento do operador poderia ter uma tradu\u00e7\u00e3o melhor para o portugu\u00eas \u2013 tivemos que trabalhar com a vers\u00e3o em ingl\u00eas. Fora isso, a m\u00e1quina em si \u00e9 excelente e eu a compraria novamente.\u201d<\/p>\n<p><strong>Michael Torres, Diretor de Opera\u00e7\u00f5es, EUA<\/strong><br \/>\n\u201cSomos uma empresa de embalagens terceirizadas em Ohio e adicionamos a ZQ60 para atender um cliente farmac\u00eautico que precisava de frascos conta-gotas de PEAD com especifica\u00e7\u00f5es muito rigorosas. O recurso de zero desperd\u00edcio foi o fator decisivo para n\u00f3s, pois anteriormente oper\u00e1vamos uma m\u00e1quina de extrus\u00e3o e sopro com uma taxa de refugo de 25-30% nesse produto, e os custos com o desperd\u00edcio de material eram insustent\u00e1veis. Desde que colocamos a ZQ60 em opera\u00e7\u00e3o, nosso custo de material para esse trabalho caiu drasticamente e nossa taxa de rejei\u00e7\u00e3o por qualidade \u00e9 essencialmente zero. Desde ent\u00e3o, adicionamos um segundo tipo de frasco na mesma m\u00e1quina, utilizando o design de molde modular.\u201d<\/p>\n<p data-path-to-node=\"0\"><b data-path-to-node=\"0\" data-index-in-node=\"0\">Sofia Reyes, Gerente de F\u00e1brica, M\u00e9xico<br \/>\n<\/b>\u201cSomos uma empresa em Monterrey que fabrica embalagens para produtos de limpeza e condimentos. Utilizamos a ZQ60 h\u00e1 10 meses para produzir garrafas de PP de 100 ml e 250 ml. A m\u00e1quina \u00e9 muito est\u00e1vel; n\u00e3o tivemos nenhum problema grave desde a instala\u00e7\u00e3o. O representante da CMN no M\u00e9xico nos deu muito apoio durante a instala\u00e7\u00e3o e nas primeiras semanas de produ\u00e7\u00e3o. A efici\u00eancia energ\u00e9tica \u00e9 notavelmente melhor do que a da nossa m\u00e1quina anterior, e a produ\u00e7\u00e3o di\u00e1ria supera o que nos foi prometido. Recomendamos sem d\u00favida a ZQ60 a qualquer pessoa que procure uma m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro de qualidade a um pre\u00e7o competitivo.\u201d<\/p>\n<p><strong>James Wilson, Vice-Presidente de Manufatura, EUA<\/strong><br \/>\n\u201cAvaliei a ZQ60 como uma alternativa usada \u00e0s m\u00e1quinas de moldagem por inje\u00e7\u00e3o e sopro de PET \u2013 quer\u00edamos um equipamento novo que oferecesse a mesma confiabilidade de marcas consolidadas. Depois de visitar a f\u00e1brica da CMN em Zhangjiagang e inspecionar o processo de fabrica\u00e7\u00e3o, fiquei convencido. J\u00e1 estamos operando a ZQ60 h\u00e1 11 meses, produzindo garrafas de bebidas de 500 ml em PCTG com 3 cavidades. A produ\u00e7\u00e3o est\u00e1 est\u00e1vel em torno de 32.000 garrafas por dia, o que corresponde ao nosso plano de produ\u00e7\u00e3o. A qualidade \u00e9 muito consistente. Fiquei particularmente impressionado com o sistema de encoder absoluto nos servomotores, o que significa que n\u00e3o h\u00e1 varia\u00e7\u00e3o na repetibilidade ao longo do tempo, ao contr\u00e1rio das m\u00e1quinas hidr\u00e1ulicas.\u201d<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>A m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro ZQ60 foi projetada com base em uma estrutura aut\u00eantica de estilo europeu, oferecendo estabilidade estrutural superior que estabelece um novo padr\u00e3o al\u00e9m dos modelos convencionais. Sua for\u00e7a de amortecimento \u00e9 aprimorada pelos componentes 20%-30% em compara\u00e7\u00e3o com os concorrentes do setor, suprimindo efetivamente a vibra\u00e7\u00e3o operacional para resultados de moldagem precisos e repet\u00edveis. O sistema de rota\u00e7\u00e3o servo padr\u00e3o da m\u00e1quina oferece uma arquitetura simplificada e opera\u00e7\u00e3o intuitiva, tornando-a a escolha ideal para fabricantes que buscam uma m\u00e1quina de moldagem por inje\u00e7\u00e3o e sopro de pl\u00e1stico de alto desempenho, capaz de atender \u00e0s exigentes demandas de produ\u00e7\u00e3o dos setores farmac\u00eautico, cosm\u00e9tico e de bebidas.<\/p>","protected":false},"featured_media":7431,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[279],"product_tag":[280,281,282,283,284,285,286,287,288,289,290,291],"class_list":{"0":"post-7511","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-injection-blow-molding-machine","7":"product_tag-all-electric-injection-blow-molding-machine","8":"product_tag-full-electric-injection-blow-molding-machine","9":"product_tag-ibm-injection-blow-molding-machine","10":"product_tag-injection-blow-molding-machine","11":"product_tag-injection-blow-molding-machine-for-sale","12":"product_tag-injection-blow-molding-machine-manufacturers","13":"product_tag-injection-blow-molding-machine-price","14":"product_tag-injection-blow-molding-machine-suppliers","15":"product_tag-injection-blowing-molding-machine","16":"product_tag-one-step-injection-blow-molding-machine","17":"product_tag-pet-injection-blow-molding-machine","18":"product_tag-plastic-injection-blow-molding-machine","20":"first","21":"instock","22":"shipping-taxable","23":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/korea-transmission.com\/pt\/wp-json\/wp\/v2\/product\/7511","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/korea-transmission.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/korea-transmission.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/korea-transmission.com\/pt\/wp-json\/wp\/v2\/comments?post=7511"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/korea-transmission.com\/pt\/wp-json\/wp\/v2\/media\/7431"}],"wp:attachment":[{"href":"https:\/\/korea-transmission.com\/pt\/wp-json\/wp\/v2\/media?parent=7511"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/korea-transmission.com\/pt\/wp-json\/wp\/v2\/product_brand?post=7511"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/korea-transmission.com\/pt\/wp-json\/wp\/v2\/product_cat?post=7511"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/korea-transmission.com\/pt\/wp-json\/wp\/v2\/product_tag?post=7511"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}